Effective COMMISSION REGULATION (EU) 2019/1390 of 31 July 2019 amending, for the purpose of its adaptation to technical progress, the Annex to Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (Text with EEA relevance)
Vyhláška č. 1390/2019
Important dates
Documents and links
COMMISSION REGULATION (EU) 2019/1390
of 31 July 2019
amending, for the purpose of its adaptation to technical progress, the Annex to Regulation (EC) No 440/2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
(Text with EEA relevance)
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC (1), and in particular Article 13(2) thereof,
Whereas:
|
(1) |
Commission Regulation (EC) No 440/2008 (2) contains the test methods for the purposes of the determination of the physicochemical properties, toxicity and ecotoxicity of chemicals to be applied for the purposes of Regulation (EC) No 1907/2006. |
|
(2) |
The Organisation for Economic Cooperation and Development (OECD) develops harmonised and internationally agreed test guidelines for the testing of chemicals for regulatory purposes. The OECD regularly issues new and revised test guidelines, taking account of scientific progress in this area. |
|
(3) |
In order to take into account technical progress and, whenever possible, to reduce the number of animals used for experimental purposes in accordance with Article 13(2) of Regulation (EC) No 1907/2006, following the adoption of relevant OECD test guidelines, two new test methods for the assessment of ecotoxicity and nine new test methods for the determination of toxicity to human health should be laid down and seven test methods should be updated. Eleven of those test methods relate to in vitro tests for skin and eye irritation/corrosion, skin sensitisation, genotoxicity and endocrine effects. Stakeholders have been consulted on the proposed amendment. |
|
(4) |
Regulation (EC) No 440/2008 should therefore be amended accordingly. |
|
(5) |
The measures provided for in this Regulation are in accordance with the opinion of the Committee established under Article 133 of Regulation (EC) No 1907/2006, |
HAS ADOPTED THIS REGULATION:
Article 1
The Annex to Regulation (EC) No 440/2008 is amended in accordance with the Annex to this Regulation.
Article 2
This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Done at Brussels, 31 July 2019.
For the Commission
The President
Jean-Claude JUNCKER
Prílohy
ANNEX
The Annex to Regulation (EC) No 440/2008 is amended as follows:
|
(1) |
In part B, Chapter B.4 is replaced by the following: "B.4 ACUTE DERMAL IRRITATION/CORROSION INTRODUCTION
INITIAL CONSIDERATIONS
PRINCIPLE OF THE IN VIVO TEST
PREPARATIONS FOR THE IN VIVO TEST Selection of animal species
Preparation of the animals
Housing and feeding conditions
TEST PROCEDURE Application of the test chemical
Dose level
Initial test (In vivo dermal irritation/corrosion test using one animal)
Confirmatory test (In vivo dermal irritation test with additional animals)
Observation period
Clinical observations and grading of skin reactions
DATA AND REPORTING
Evaluation of results
Test report
LITERATURE
Appendix DEFINITIONS Chemical is a substance or a mixture. Dermal irritation is the production of reversible damage of the skin following the application of a test chemical for up to 4 hours. Dermal corrosion is the production of irreversible damage of the skin; namely, visible necrosis through the epidermis and into the dermis, following the application of a test chemical for up to four hours. Corrosive reactions are typified by ulcers, bleeding, bloody scabs, and, by the end of observation at 14 days, by discolouration due to blanching of the skin, complete areas of alopecia, and scars. Histopathology should be considered to evaluate questionable lesions. Test chemical is any substance or mixture tested using this test method |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(2) |
In Part B, Chapter B.17 is replaced by the following: "B.17 IN VITRO MAMMALIAN CELL GENE MUTATION TESTS USING THE HPRT AND XPRT GENES INTRODUCTION
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DESCRIPTION OF THE METHOD Preparations Cells
Media and culture conditions
Preparation of cultures
Metabolic activation
Test chemical preparation
TEST CONDITIONS Solvents
Measuring cytotoxicity and choosing exposure concentrations
Controls
Table 1 Reference substances recommended for assessing laboratory proficiency and for selection of positive controls
PROCEDURE Treatment with test chemical
Phenotypic expression time and measuring mutant frequency
Proficiency of the laboratory
Historical control data
DATA AND REPORTING Presentation of the results
Acceptability Criteria
Evaluation and interpretation of results
Test report
LITERATURE
Appendix 1 DEFINITIONS Base pair substitution mutagens: chemicals that cause substitution of base pairs in the DNA. Chemical: A substance or a mixture. Cloning efficiency: The percentage of cells plated at a low density that are able to grow into a colony that can be counted. Concentrations: refer to final concentrations of the test chemical in culture medium Cytotoxicity: For the assays covered in this test method, cytotoxicity is identified as a reduction in relative survival of the treated cells as compared to the negative control (see specific paragraph). Forward mutation: a gene mutation from the parental type to the mutant form which gives rise to an alteration or a loss of the enzymatic activity or the function of the encoded protein. Frameshift mutagens: chemicals which cause the addition or deletion of single or multiple base pairs in the DNA molecule. Genotoxic: a general term encompassing all types of DNA or chromosomal damage, including DNA breaks, adducts, rearrangements, mutations, chromosome aberrations, and aneuploidy. Not all types of genotoxic effects result in mutations or stable chromosomal damage HAT medium: medium containing Hypoxanthine, Aminopterin and Thymidine, used for cleansing of Hprt mutants. Mitotic recombination: during mitosis, recombination between homologous chromatids possibly resulting in the induction of DNA double strand breaks or in a loss of heterozygosity. MPA medium: medium containing Xanthine, Adenine, Thymidine, Aminopterin and Mycophenolic acid, used for cleansing of Xprt mutants. Mutagenic: produces a heritable change of DNA base-pair sequences(s) in genes or of the structure of chromosomes (chromosome aberrations). Mutant frequency (MF): the number of mutant colonies observed divided by the number of cells plated in selective medium, corrected for cloning efficiency (or viability) at the time of selection. Phenotypic expression time: The time after treatment during which the genetic alteration is fixed within the genome and any preexisting gene products are depleted to the point that the phenotypic trait is altered. Relative survival (RS): RS is used as the measure of treatment-related cytotoxicity. RS is cloning efficiency (CE) of cells plated immediately after treatment adjusted by any loss of cells during treatment as compared with cloning efficiency in negative controls (assigned a survival of 100 %). S9 liver fractions: supernatant of liver homogenate after 9 000g centrifugation, i.e. raw liver extract S9 mix: mix of the liver S9 fraction and cofactors necessary for metabolic enzyme activity. Solvent control: General term to define the control cultures receiving the solvent alone used to dissolve the test chemical. Test chemical: Any substance or mixture tested using this test method. Untreated control: cultures that receive no treatment (i.e. neither test chemical nor solvent) but are processed concurrently and in the same way as the cultures receiving the test chemical UVCB: Chemical Substances of Unknown or Variable Composition, Complex Reaction Products and Biological Materials Appendix 2 FORMULAS FOR ASSESSMENT OF CYTOTOXICITY AND MUTANT FREQUENCY Cytotoxicity is evaluated by relative survival, i. e., cloning efficiency (CE) of cells plated immediately after treatment adjusted by any loss of cells during treatment as compared with adjusted cloning efficiency in negative controls (assigned a survival of 100 %) (see RS formula below). Adjusted CE for a culture treated by a test chemical is calculated as:
RS for a culture treated by a test chemical is calculated as:
Mutant frequency is the cloning efficiency of mutant colonies in selective medium divided by the cloning efficiency in non-selective medium measured for the same culture at the time of selection.
When plates are used for cloning efficiency:
When micro-well plates are used for cloning efficiency:
|
|
(3) |
In Part B, Chapter B.22 is replaced by the following: "B.22 RODENT DOMINANT LETHAL TEST INTRODUCTION
INITIAL CONSIDERATIONS
PRINCIPLE OF THE TEST
VERIFICATION OF LABORATORY PROFICIENCY
DESCRIPTION OF THE METHOD Preparations Selection of animal species
Animal housing and feeding conditions
Preparation of the animals
Preparation of doses
Test Conditions Solvent/vehicle
Positive controls
Table 1 Examples of Positive Control Substances.
Negative controls
PROCEDURE Number of Animals
Administration Period and Mating Intervals
Dose Levels
Administration of Doses
Observations
Tissue Collection and Processing
DATA AND REPORTING Treatment of Results
Acceptability Criteria
Evaluation and Interpretation of Results
Test Report
LITERATURE
Appendix 1 DEFINITIONS Chemical: A substance or a mixture Corpora luteum (lutea): the hormonal secreting structure formed on the overy at the site of a follicle that has released the egg. The number of corpora lutea in the ovaries corresponds to the number of eggs that were ovulated. Dominant Lethal Mutation: a mutation occurring in a germ cell, or is fixed after fertilisation, that causes embryonic or foetal death. Fertility rate: the number of mated pregnant female over the number of mated females. Mating interval: the time between the end of exposure and mating of treated males. By controlling this interval, chemical effects on different germ cell types can be assessed. In the mouse mating during the 1, 2, 3, 4, 5, 6, 7 and 8 week after the end of exposure measures effects in sperm, condensed spermatids, round spermatids, pachytene spermatocytes, early spermatocytes, differentiated spermatogonia, differentiating spermatogonia and stem cell spermatogonia. Preimplantation loss: the difference between the number of implants and the number of corpora lutea. It can also be estimated by comparing the total implants per female in treated and control groups. Postimplantation loss: the ratio of dead implant in the treated group compared to the ratio of dead to total implants in the control group. Test chemical: Any substance or mixture tested using this test method. UVCB: Chemical Substance of Unknown or Variable Composition, Complex Reaction Products and Biological Materials Appendix 2 TIMING OF SPERMATOGENESIS IN MAMMALS Fig.1: Comparison of the duration (days) of male germ cell development in mice, rats and humans. DNA repair does not occur during the periods indicated by shading. A schematic of spermatogenesis in the mouse, rat and human is shown above (taken from Adler, 1996). Undifferentiated spermatogonia include: A-single; A-paired; and A-aligned spermatogonia (Hess and de Franca, 2008). A-single is considered the true stem cells; therefore, to assess effects on stem cells at least 49 days (in the mouse) must pass between the last injection of the test chemical and mating. References Adler, ID (1996). Comparison of the duration of spermatogenesis between rodents and humans. Mutat Res, 352:169-172. Hess, RA, De Franca LR (2008). Spermatogenesis and cycle of the seminiferous epithelium. In: Molecular Mechanisms in Spermatogenesis, C. Yan Cheng (Ed), Landes Biosciences and Springer Science&Business Media:1-15. |
|
(4) |
In Part B, Chapter B.23 is replaced by the following: "B.23 MAMMALIAN SPERMATOGONIAL CHROMOSOMAL ABERRATION TEST INTRODUCTION
INITIAL CONSIDERATIONS
PRINCIPLE OF THE TEST METHOD
VERIFICATION OF LABORATORY PROFICIENCY
DESCRIPTION OF THE METHOD Preparations Selection of animal species
Animal Housing and feeding conditions
Preparation of the animals
Preparation of doses
Test conditions - Solvent/vehicle
Positive controls
Table 1 Examples of positive control substances.
Negative controls
PROCEDURE Number of animals
Treatment schedule
Dose levels
Administration of doses
Observations
Chromosome preparation
Analysis
DATA AND REPORTING Treatment of results
Acceptability Criteria
Evaluation and interpretation of results
Test report
LITERATURE
Appendix DEFINITIONS Aneuploidy: any deviation from the normal diploid (or haploid) number of chromosomes by a single chromosome or more than one, but not by entire set(s) of chromosomes (polyploidy). Centromere: Region(s) of a chromosome with which spindle fibers are associated during cell division, allowing orderly movement of daughter chromosomes to the poles of the daughter cells. Chemical: A substance or a mixture Chromosome diversity: diversity of chromosome shapes (e.g. metacentrique, acrocentriques, etc) and sizes. Chromatid-type aberration: structural chromosome damage expressed as breakage of single chromatids or breakage and reunion between chromatids. Chromosome-type aberration: structural chromosome damage expressed as breakage, or breakage and reunion, of both chromatids at an identical site. Clastogen: any chemical which causes structural chromosomal aberrations in populations of cells or organisms. Gap: an achromatic lesion smaller than the width of one chromatid, and with minimum misalignment of the chromatids. Genotoxic: a general term encompassing all types of DNA or chromosome damage, including breaks, deletions, adducts, nucleotides modifications and linkages, rearrangements, mutations, chromosome aberrations, and aneuploidy. Not all types of genotoxic effects result in mutations or stable chromosome damage. Mitotic index (MI): the ratio of cells in metaphase divided by the total number of cells observed in a population of cells; an indication of the degree of proliferation of that population. Mitosis: division of the cell nucleus usually divided into prophase, prometaphase, metaphase, anaphase, and telophase. Mutagenic: produces a heritable change of DNA base-pair sequence(s) in genes or of the structure of chromosomes (chromosome aberrations). Numerical abnormality: a change in the number of chromosomes from the normal number characteristic of the animals utilised. Polyploidy: a multiple of the haploid chromosome number (n) other than the diploid number (i.e., 3n, 4n and so on). Structural aberration: a change in chromosome structure detectable by microscopic examination of the metaphase stage of cell division, observed as deletions and fragments, exchanges. Test chemical: Any substance or mixture tested using this test method. UVCB: Chemical Substances of Unknown or Variable Composition, Complex Reaction Products and Biological Materials |
|
(5) |
In Part B, Chapter B.40 is replaced by the following: "B.40 IN VITRO SKIN CORROSION: TRANSCUTANEOUS ELECTRICAL RESISTANCE TEST METHOD (TER) INTRODUCTION
DEFINITIONS
INITIAL CONSIDERATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
Table 1 List of Proficiency Substances (2)
PROCEDURE
Animals
Preparation of the skin discs
Application of the test chemical and control substances
TER measurements
Dye Binding Methods
Sulforhodamine B dye application and removal
Calculation of dye content
Acceptability Criteria
Interpretation of results
DATA AND REPORTING Data
Test report
LITERATURE
Figure 1 Apparatus for the Rat Skin Ter Assay Figure 2 Dimensions Of The Polytetrafluoroethylene (Ptfe) And Receptor Tubes And Electrodes Used Critical factors of the apparatus shown above:
Appendix DEFINITIONS Accuracy : The closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of relevance. The term is often used interchangeably with “concordance” to mean the proportion of correct outcomes of a test method (20). C : Corrosive. Chemical : A substance or a mixture. Concordance : A measure of test method performance for test methods that give a categorical result, and is one aspect of relevance. The term is sometimes used interchangeably with accuracy, and is defined as the proportion of all chemicals tested that are correctly classified as positive or negative. Concordance is highly dependent on the prevalence of positives in the types of test chemical being examined (20). GHS (Globally Harmonized System of Classification and Labelling of Chemicals (UN)) : A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1). IATA : Integrated Approach on Testing and Assessment. Mixture : A mixture or solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. NC : Non corrosive. OD : Optical Density. PC : Positive Control, a replicate containing all components of a test system and treated with a substance known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Performance standards (PS) : Standards, based on a validated test method, that provide a basis for evaluating the comparability of a proposed test method that is mechanistically and functionally similar. Included are; (i) essential test method components; (ii) a minimum list of Reference Chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (iii) the similar levels of reliability and accuracy, based on what was obtained for the validated test method, that the proposed test method should demonstrate when evaluated using the minimum list of Reference Chemicals. Relevance : Description of relationship of the test method to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test method correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (20). Reliability : Measures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility (20). Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (20). Skin corrosion in vivo : The production of irreversible damage of the skin; namely, visible necrosis through the epidermis and into the dermis, following the application of a test chemical for up to four hours. Corrosive reactions are typified by ulcers, bleeding, bloody scabs, and, by the end of observation at 14 days, by discoloration due to blanching of the skin, complete areas of alopecia, and scars. Histopathology should be considered to evaluate questionable lesions. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (20). Substance : A chemical element and its compounds in the natural state or obtained by any production process, including any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. (Testing) run : A single test chemical concurrently tested in a minimum of three replicate skin discs. Test chemical : Any substance or mixture tested using this test method. Transcutaneous Electrical Resistance (TER) : is a measure of the electrical impedance of the skin, as a resistance value in kilo Ohms. A simple and robust method of assessing barrier function by recording the passage of ions through the skin using a Wheatstone bridge apparatus. UVCB : Substances of unknown or variable composition, complex reaction products or biological materials. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(6) |
In Part B, Chapter B.40bis is replaced by the following: "B.40bis IN VITRO SKIN CORROSION: RECONSTRUCTED HUMAN EPIDERMIS (RhE) TEST METHOD INTRODUCTION
DEFINITIONS
INITIAL CONSIDERATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
RHE TEST METHOD COMPONENTS General Conditions
Functional Conditions Viability
Barrier function
Morphology
Reproducibility
Quality control (QC)
Table 3 QC batch release criteria
Application of the Test Chemical and Control Chemicals
Cell Viability Measurements
Acceptability Criteria
Interpretation of Results and Prediction Model
DATA AND REPORTING Data
Test report
LITERATURE
Appendix 1 DEFINITIONS Accuracy : The closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of relevance. The term is often used interchangeably with “concordance” to mean the proportion of correct outcomes of a test method (25). Cell viability : Parameter measuring total activity of a cell population e.g. as ability of cellular mitochondrial dehydrogenases to reduce the vital dye MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide, Thiazolyl blue), which depending on the endpoint measured and the test design used, correlates with the total number and/or vitality of living cells. Chemical : A substance or a mixture. Concordance : This is a measure of test method performance for test methods that give a categorical result, and is one aspect of relevance. The term is sometimes used interchangeably with accuracy, and is defined as the proportion of all chemicals tested that are correctly classified as positive or negative. Concordance is highly dependent on the prevalence of positives in the types of test chemical being examined (25). ET50 : Can be estimated by determination of the exposure time required to reduce cell viability by 50 % upon application of the benchmark chemical at a specified, fixed concentration, see also IC50. GHS (Globally Harmonized System of Classification and Labelling of Chemicals) : A system proposing the classification of chemicals (substances and mixtures) according to standardized types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1). HPLC : High Performance Liquid Chromatography. IATA : Integrated Approach on Testing and Assessment. IC50 : Can be estimated by determination of the concentration at which a benchmark chemical reduces the viability of the tissues by 50 % (IC50) after a fixed exposure time, see also ET50. Infinite dose : Amount of test chemical applied to the epidermis exceeding the amount required to completely and uniformly cover the epidermis surface. Mixture : A mixture or solution composed of two or more substances in which they do not react. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). MTT : 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide; Thiazolyl blue tetrazolium bromide. Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration > 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. NC : Non corrosive. NSCkilled control : Non-Specific Colour control in killed tissues. NSCliving control : Non-Specific Colour control in living tissues. NSMTT : Non-Specific MTT reduction. OD : Optical Density PC : Positive Control, a replicate containing all components of a test system and treated with a chemical known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Performance standards (PS) : Standards, based on a validated test method, that provide a basis for evaluating the comparability of a proposed test method that is mechanistically and functionally similar. Included are; (i) essential test method components; (ii) a minimum list of Reference Chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (iii) the similar levels of reliability and accuracy, based on what was obtained for the validated test method, that the proposed test method should demonstrate when evaluated using the minimum list of Reference Chemicals (25). Relevance : Description of relationship of the test method to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test method correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (25). Reliability : Measures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility (25). Run : A run consists of one or more test chemicals tested concurrently with a negative control and with a PC. Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (25). Skin corrosion in vivo : The production of irreversible damage of the skin; namely, visible necrosis through the epidermis and into the dermis, following the application of a test chemical for up to four hours. Corrosive reactions are typified by ulcers, bleeding, bloody scabs, and, by the end of observation at 14 days, by discoloration due to blanching of the skin, complete areas of alopecia, and scars. Histopathology should be considered to evaluate questionable lesions. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (25). Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Test chemical : Any substance or mixture tested using this test method. UPLC : Ultra-High Performance Liquid Chromatography. UVCB : substances of unknown or variable composition, complex reaction products or biological materials. Appendix 2 MAIN COMPONENTS OF THE RHE TEST MODELS VALIDATED FOR SKIN CORROSION TESTING
Appendix 3 PERFORMANCE OF TEST MODELS FOR SUB-CATEGORISATION The table below provides the performances of the four test models calculated based on a set of 80 chemicals tested by the four test developers. Calculations were performed by the OECD Secretariat, reviewed and agreed by an expert subgroup (21) (23). EpiSkin™, EpiDerm™,SkinEthic™ and epiCS® test models are able to sub-categorise (i.e. 1A versus 1B-and-1C versus NC) Performances, overclassification rates, underclassification rates, and accuracy (Predictive capacity) of the four test models based on a set of 80 chemicals all tested over 2 or 3 runs in each test model:
NC: Non-corrosive Appendix 4 Key parameters and acceptance criteria for qualification of an HPLC/UPLC-spectrophotometry system for measurement of MTT formazan extracted from RhE tissue
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(7) |
In Part B, Chapter B.46 is replaced by the following: "B.46 IN VITRO SKIN IRRITATION: RECONSTRUCTED HUMAN EPIDERMIS TEST METHOD INTRODUCTION
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
RHE TEST METHOD COMPONENTS General conditions
Functional conditions Viability
Barrier function
Morphology
Reproducibility
Quality control (QC)
Application of the Test Chemical and Control Chemicals
Cell Viability Measurements
Acceptability Criteria
Interpretation of Results and Prediction Model
DATA AND REPORTING Data
Test Report
LITERATURE
Appendix 1 DEFINITIONS Accuracy : The closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of relevance. The term is often used interchangeably with “concordance” to mean the proportion of correct outcomes of a test method (9). Cell viability : Parameter measuring total activity of a cell population e.g. as ability of cellular mitochondrial dehydrogenases to reduce the vital dye MTT (3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide, Thiazolyl blue), which depending on the endpoint measured and the test design used, correlates with the total number and/or vitality of living cells. Chemical : means a substance or a mixture. Concordance : This is a measure of performance for test models that give a categorical result, and is one aspect of relevance. The term is sometimes used interchangeably with accuracy, and is defined as the proportion of all chemicals tested that are correctly classified as positive or negative. Concordance is highly dependent on the prevalence of positives in the types of test chemical being examined (9). ET50 : Can be estimated by determination of the exposure time required to reduce cell viability by 50 % upon application of the benchmark chemical at a specified, fixed concentration, see also IC50. GHS (Globally Harmonized System of Classification and Labelling of Chemicals by the United Nations (UN)) : A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1). HPLC : High Performance Liquid Chromatography. IATA : Integrated Approach on Testing and Assessment IC50 : Can be estimated by determination of the concentration at which a benchmark chemical reduces the viability of the tissues by 50 % (IC50) after a fixed exposure time, see also ET50. Infinite dose : Amount of test chemical applied to the epidermis exceeding the amount required to completely and uniformly cover the epidermis surface. Mixture : A mixture or a solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). MTT : 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide; Thiazolyl blue tetrazolium bromide. Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. NSCkilled : Non-Specific Colour in killed tissues. NSCliving : Non-Specific Colour in living tissues. NSMTT : Non-Specific MTT reduction. Performance standards (PS) : Standards, based on a validated test method, that provide a basis for evaluating the comparability of a proposed test method that is mechanistically and functionally similar. Included are; (i) essential test method components; (ii) a minimum list of Reference Chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (iii) the comparable levels of accuracy and reliability, based on what was obtained for the validated test method, that the proposed test method should demonstrate when evaluated using the minimum list of Reference Chemicals (9). PC : Positive Control, a replicate containing all components of a test system and treated with a chemical known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Relevance : Description of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (9). Reliability : Measures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility (9). Replacement test : A test which is designed to substitute for a test that is in routine use and accepted for hazard identification and/or risk assessment, and which has been determined to provide equivalent or improved protection of human or animal health or the environment, as applicable, compared to the accepted test, for all possible testing situations and chemicals (9). Run : A run consists of one or more test chemicals tested concurrently with a negative control and with a PC. Sensitivity : The proportion of all positive/active test chemicals that are correctly classified by the test. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (9). Skin irritation in vivo : The production of reversible damage to the skin following the application of a test chemical for up to 4 hours. Skin irritation is a locally arising reaction of the affected skin tissue and appears shortly after stimulation (38). It is caused by a local inflammatory reaction involving the innate (non-specific) immune system of the skin tissue. Its main characteristic is its reversible process involving inflammatory reactions and most of the clinical characteristic signs of irritation (erythema, oedema, itching and pain) related to an inflammatory process. Specificity : The proportion of all negative/inactive test chemicals that are correctly classified by the test. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (9). Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Test chemical : Any substance or mixture tested using this test method. UPLC : Ultra-High Performance Liquid Chromatography. UVCB : substances of unknown or variable composition, complex reaction products or biological materials. Appendix 2 TEST MODELS INCLUDED IN THIS TEST METHOD
Appendix 3 PROTOCOL PARAMETERS SPECIFIC TO EACH OF THE TEST MODELS INCLUDED IN THIS TEST METHOD The RhE models do show very similar protocols and notably all use a post-incubation period of 42 hours (32) (33) (34) (35). Variations concern mainly three parameters relating to the different barrier functions of the test models and listed here: A) pre-incubation time and volume, B) Application of test chemicals and C) Post-incubation volume.
Appendix 4 KEY PARAMETERS AND ACCEPTANCE CRITERIA FOR QUALIFICATION OF AN HPLC/UPLC-SPECTROPHOTOMETRY SYSTEM FOR MEASUREMENT OF MTT FORMAZAN EXTRACTED FROM RHE TISSUES
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(8) |
In Part B, the following Chapters are added: "B.63 REPRODUCTION/DEVELOPMENTAL TOXICITY SCREENING TEST INTRODUCTION
INITIAL CONSIDERATIONS
PRINCIPLE OF THE TEST
DESCRIPTION OF THE METHOD Selection of animal species
Housing and feeding
Preparation of the animals
Preparation of doses
PROCEDURE Number and sex of animals
Dosage
Limit test
Administration of doses
Experimental schedule
Mating procedure
Litter size
In life observations Clinical observations
Body weight and food/water consumption
Oestrous cycles
Offspring parameters
Clinical biochemistry
All blood samples are stored under appropriate conditions. Blood samples from the day 13 pups and the adult males are assessed for serum levels for thyroid hormones (T4). Further assessment of T4 in blood samples from the dams and day 4 pups is done if relevant. As an option other hormones may be measured if relevant. Pup blood can be pooled by litter for thyroid hormone analyses. Thyroid hormones (T4 and TSH) should preferably be measured as ‘total’.
Pathology Gross necropsy
Histopathology
DATA AND REPORTING Data
Evaluation of results
Test report
Interpretation of results
LITERATURE
Appendix 1 DEFINITIONS (SEE ALSO OECD GD 150 (6)) Androgenicity is the capability of a chemical to act like a natural androgenic hormone (e.g. testosterone) in a mammalian organism. Antiandrogenicity is the capability of a chemical to suppress the action of a natural androgenic hormone (e.g. testosterone) in a mammalian organism. Antioestrogenicity is the capability of a chemical to suppress the action of a natural oestrogenic hormone (e.g. oestradiol 17ß) in a mammalian organism. Antithyroid activity is the capability of a chemical to suppress the action of a natural thyroid hormone (e.g. T3) in a mammalian organism. Chemical is a substance or a mixture. Developmental toxicity: the manifestation of reproductive toxicity, representing pre-, peri- post-natal, structural, or functional disorders in the progeny. Dosage is a general term comprising of dose, its frequency and the duration of dosing. Dose is the amount of test chemical administered. The dose is expressed as weight of test chemical per unit body weight of test animal per day (e.g. mg/kg body weight/day), or as a constant dietary concentration. Evident toxicity is a general term describing clear signs of toxicity following administration of test chemical. These should be sufficient for hazard assessment and should be such that an increase in the dose administered can be expected to result in the development of severe toxic signs and probable mortality. Impairment of fertility represents disorders of male or female reproductive functions or capacity. Maternal toxicity: adverse effects on gravid females, occurring either specifically (direct effect) or not specifically (indirect effect). NOAEL is the abbreviation for no-observed-adverse effect level. This is the highest dose level where no adverse treatment-related findings are observed due to treatment. Oestrogenicity is the capability of a chemical to act like a natural oestrogenic hormone (e.g. oestradiol 17ß) in a mammalian organism. Reproduction toxicity represents harmful effects on the progeny and/or an impairment of male and female reproductive functions or capacity. Test chemical is any substance or mixture tested using this test method. Thyroid activity is the capability of a chemical to act like a natural thyroid hormone (e.g. T3) in a mammalian organism. Validation is a scientific process designed to characterise the operational requirements and limitations of a test method and to demonstrate its reliability and relevance for a particular purpose. Appendix 2 DIAGRAM OF THE EXPERIMENTAL SCHEDULE INDICATING THE MAXIMUM STUDY DURATION, BASED ON A FULL 14-DAY MATING PERIOD Appendix 3 TABULAR SUMMARY REPORT OF EFFECTS ON REPRODUCTION/DEVELOPMENT
B.64 COMBINED REPEATED DOSE TOXICITY STUDY WITH THE REPRODUCTION/DEVELOPMENTAL TOXICITY SCREENING TEST INTRODUCTION
INITIAL CONSIDERATIONS
PRINCIPLE OF THE TEST
DESCRIPTION OF THE METHOD Selection of animal species
Housing and feeding
Preparation of the animals
Preparation of doses
PROCEDURE Number and sex of animals
Dosage
Limit test
Administration of doses
Experimental schedule
Oestrous cycles
Mating procedure
Litter size
Observations
Body weight and food/water consumption
Haematology
Clinical biochemistry
PATHOLOGY Gross necropsy
Histopathology
DATA AND REPORTING Data
Evaluation of results
Test report
Interpretation of Results
LITERATURE
Appendix 1 DEFINITIONS (SEE ALSO (20) OECD GD 150) Androgenicity is the capability of a chemical to act like a natural androgenic hormone (e.g. testosterone) in a mammalian organism. Antiandrogenicity is the capability of a chemical to suppress the action of a natural androgenic hormone (e.g. testosterone) in a mammalian organism. Antioestrogenicity is the capability of a chemical to suppress the action of a natural oestrogenic hormone (e.g. oestradiol 17ß) in a mammalian organism. Antithyroid activity is the capability of a chemical to suppress the action of a natural thyroid hormone (e.g. T3) in a mammalian organism. Chemical is a substance or a mixture. Developmental toxicity: the manifestation of reproductive toxicity, representing pre-, peri- post-natal, structural, or functional disorders in the progeny. Dose is the amount of test chemical administered. The dose is expressed as weight of test chemical per unit body weight of test animal per day (e.g. mg/kg body weight/day), or as a constant dietary concentration. Dosage is a general term comprising dose, its frequency and the duration of dosing. Evident toxicity is a general term describing clear signs of toxicity following administration of test chemical. These should be sufficient for hazard assessment and should be such that an increase in the dose administered can be expected to result in the development of severe toxic signs and probable mortality. Impairment of fertility represents disorders of male or female reproductive functions or capacity. Maternal toxicity: adverse effects on gravid females, occurring either specifically (direct effect) or not specifically (indirect effect) and being related to the gravid state. NOAEL is the abbreviation for no-observed-adverse-effect level. This is the highest dose level where no adverse treatment-related findings are observed due to treatment. Oestrogenicity is the capability of a chemical to act like a natural oestrogenic hormone (e.g. oestradiol 17ß) in a mammalian organism. Reproduction toxicity represents harmful effects on the progeny and/or an impairment of male and female reproductive functions or capacity. Test chemical is any substance or mixture tested using this test method. Thyroid activity is the capability of a chemical to act like a natural thyroid hormone (e.g. T3) in a mammalian organism. Validation is a scientific process designed to characterise the operational requirements and limitations of a test method and to demonstrate its reliability and relevance for a particular purpose. Appendix 2 DIAGRAM OF THE EXPERIMENTAL SCHEDULE, INDICATING THE MAXIMUM STUDY DURATION, BASED ON A FULL 14-DAY MATING PERIOD Appendix 3 TABULAR SUMMARY REPORT OF EFFECTS ON REPRODUCTION/DEVELOPMENT
B.65 IN VITRO MEMBRANE BARRIER TEST METHOD FOR SKIN CORROSION INTRODUCTION
DEFINITIONS
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
Test Chemical Compatibility Test
Test Chemical Timescale Category Test
MEMBRANE BARRIER TEST METHOD COMPONENTS Membrane Barrier
Chemical Detection System (CDS)
TEST PERFORMANCE Assembly of the Test Method Components
Application of the Test Chemical
Measurement of Membrane Barrier Penetrations
Controls
Study Acceptability Criteria
Interpretation of Results and Corrosivity Classification of Test Chemicals
DATA AND REPORTING Data
Test Report
LITERATURE
Appendix DEFINITIONS Accuracy : The closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of relevance. The term is often used interchangeably with “concordance” to mean the proportion of correct outcomes of a test method (9). Chemical : A substance or a mixture. Chemical Detection System (CDS) : A visual or electronic measurement system with an indicator solution that responds to the presence of a test chemical, e.g. by a change in a pH indicator dye, or combination of dyes, that will show a colour change in response to the presence of the test chemical or by other types of chemical or electrochemical reactions. Concordance : This is a measure of test method performance for test methods that give a categorical result, and is one aspect of relevance. The term is sometimes used interchangeably with accuracy, and is defined as the proportion of all chemicals tested that are correctly classified as positive or negative. Concordance is highly dependent on the prevalence of positives in the types of test chemical being examined (9). GHS (Globally Harmonized System of Classification and Labelling of Chemicals) : A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1). IATA : Integrated Approach on Testing and Assessment. Mixture : A mixture or solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. NC : Non corrosive. Performance standards : Standards, based on a validated test method, that provide a basis for evaluating the comparability of a proposed test method that is mechanistically and functionally similar. Included are (i) essential test method components; (ii) a minimum list of Reference Chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (iii) the similar levels of reliability and accuracy, based on what was obtained for the validated test method, that the proposed test method should demonstrate when evaluated using the minimum list of Reference Chemicals (9). Relevance : Description of relationship of the test method to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test method correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (9). Reliability : Measures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility (9). Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (9). Skin corrosion in vivo : The production of irreversible damage of the skin; namely, visible necrosis through the epidermis and into the dermis, following the application of a test chemical for up to four hours. Corrosive reactions are typified by ulcers, bleeding, bloody scabs, and, by the end of observation at 14 days, by discoloration due to blanching of the skin, complete areas of alopecia, and scars. Histopathology should be considered to evaluate questionable lesions. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test method. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (9). Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Test chemical : Any substance or mixture tested using this test method. UVCB : Substances of unknown or variable composition, complex reaction products or biological materials. B.66 STABLY TRANSFECTED TRANSACTIVATION IN VITRO ASSAYS TO DETECT ESTROGEN RECEPTOR AGONISTS AND ANTAGONISTS GENERAL INTRODUCTION OECD Performance-Based Test Guideline
Background and principles of the assays included in this test method
Scope and limitations related to the TA assays
Table 1 Overview of the Results from STTA and VM7Luc ER TA Assays for Substances Tested in Both Agonist Assays and Classified as ER Agonists (POS) or Negatives (NEG)
Table 2 Comparison of Results from STTA and VM7Luc ER TA Assays for Substances Tested in Both Antagonist Assays and Classified as ER Antagonists (POS) or Negatives (NEG)
ER TA ASSAY COMPONENTS Essential Assay Components
Controls
Standard Quality Control Procedures
Demonstration of Laboratory Proficiency
Table 3 List of (14) Proficiency Substances for agonist assay (53)
Table 4 List of (10) Proficiency Substances for antagonist assay
Test Run Acceptability Criteria
Analysis of data
General Data Interpretation Criteria
Test Report
LITERATURE
Appendix 1 DEFINITIONS AND ABBREVIATIONS Acceptability criteria : Minimum standards for the performance of experimental controls and reference standards. All acceptability criteria should be met for an experiment to be considered valid. Accuracy (concordance) : The closeness of agreement between assay results and an accepted reference values. It is a measure of assay performance and one aspect of relevance. The term is often used interchangeably with “concordance” to mean the proportion of correct outcomes of a assay (1). Agonist : A substance that produces a response, e.g. transcription, when it binds to a specific receptor. Antagonist : A type of receptor ligand or chemical that does not provoke a biological response itself upon binding to a receptor, but blocks or dampens agonist-mediated responses. Anti-estrogenic activity : the capability of a chemical to suppress the action of 17β-estradiol mediated through estrogen receptors. Cell morphology : The shape and appearance of cells grown in a monolayer in a single well of a tissue culture plate. Cells that are dying often exhibit abnormal cell morphology. CF : The OECD Conceptual Framework for the Testing and Evaluation of Endocrine Disrupters. Charcoal/dextran treatment : Treatment of serum used in cell culture. Treatment with charcoal/dextran (often referred to as “stripping”) removes endogenous hormones and hormone-binding proteins. Chemical : A substance or a mixture. Cytotoxicity : Harmful effects to cell structure or function that can ultimately cause cell death and can be reflected by a reduction in the number of cells present in the well at the end of the exposure period or a reduction of the capacity for a measure of cellular function when compared to the concurrent vehicle control. CV : Coefficient of variation DCC-FBS : Dextran-coated charcoal treated fetal bovine serum. DMEM : Dulbecco’s Modification of Eagle’s Medium DMSO : Dimethyl sulfoxide E2 : 17β-estradiol EC50 : The half maximal effective concentration of a test chemical. ED : Endocrine disruption hERα : Human estrogen receptor alpha hERß : Human estrogen receptor beta EFM : Estrogen-free medium. Dulbecco’s Modification of Eagle’s Medium (DMEM) supplemented with 4.5 % charcoal/dextran-treated FBS, 1,9 % L-glutamine, and 0,9 % Pen-Strep. ER : Estrogen receptor ERE : Estrogen response element Estrogenic activity : The capability of a chemical to mimic 17β-estradiol in its ability to bind to and activate estrogen receptors. hERα-mediated estrogenic activity can be detected with this test method. ERTA : Estrogen Receptor Trans Activation FBS : Fetal bovine serum HeLa : An immortal human cervical cell line HeLa9903 : A HeLa cell subclone into which hERα and a luciferase reporter gene have been stably transfected IC50 : The half maximal effective concentration of an inhibitory test chemical. ICCVAM : The Interagency Coordinating Committee on the Validation of Alternative Methods. Inter-laboratory reproducibility : A measure of the extent to which different qualified laboratories, using the same protocol and testing the same substances, can produce qualitatively and quantitatively similar results. Interlaboratory reproducibility is determined during the prevalidation and validation processes, and indicates the extent to which an assay can be successfully transferred between laboratories, also referred to as between-laboratory reproducibility (1). Intra-laboratory reproducibility : A determination of the extent that qualified people within the same laboratory can successfully replicate results using a specific protocol at different times. Also referred to as “within-laboratory reproducibility” (1). LEC : Lowest effective concentration is the lowest concentration of test chemical that produces a response (i.e. the lowest test chemical concentration at which the fold induction is statistically different from the concurrent vehicle control). Me-too test : A colloquial expression for an assay that is structurally and functionally similar to a validated and accepted reference test method. Interchangeably used with similar test method. MT : Metallothionein MMTV : Mouse Mammary Tumor Virus OHT : 4-Hydroxytamoxifen PBTG : Performance-Based Test Guideline PC (Positive control) : a strongly active substance, preferably 17ß-estradiol that is included in all tests to help ensure proper functioning of the assay. PC10 : the concentration of a test chemical at which the measured activity in an agonist assay is 10 % of the maximum activity induced by the PC (E2 at 1nM for the STTA assay) in each plate. PC50 : the concentration of a test chemical at which the measured activity in an agonist assay is 50 % of the maximum activity induced by the PC (E2 at the reference concentration specified in the test method) in each plate. PCMax : the concentration of a test chemical inducing the RPCMax Performance standards : Standards, based on a validated assay, that provide a basis for evaluating the comparability of a proposed assay that is mechanistically and functionally similar. Included are (1) essential assay components; (2) a minimum list of reference chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (3) the comparable levels of accuracy and reliability, based on what was obtained for the validated test method, that the proposed assay should demonstrate when evaluated using the minimum list of reference chemicals (1). Proficiency substances : A subset of the reference substances included in the Performance Standards that can be used by laboratories to demonstrate technical competence with a standardised test method. Selection criteria for these substances typically include that they represent the range of responses, are commercially available, and have high quality reference data available. Proficiency : The demonstrated ability to properly conduct an assay prior to testing unknown substances. Reference estrogen (Positive control, PC) : 17β-estradiol (E2, CAS 50-28-2). Reference standard : a reference substance used to demonstrate the adequacy of a assay. 17β-estradiol is the reference standard for the STTA and VM7Luc ER TA assays. Reference test methods : The assays upon which PBTG 455 is based. Relevance : Description of relationship of an assay to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the assay correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of an assay (1). Reliability : Measure of the extent that an assay can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility. RLU : Relative Light Units RNA : Ribonucleic Acid RPCMax : maximum level of response induced by a test chemical, expressed as a percentage of the response induced by 1 nM E2 on the same plate RPMI : RPMI 1640 medium supplemented with 0,9 % Pen-Strep and 8.0 % fetal bovine serum (FBS) Run : An individual experiment that evaluates chemical action on the biological outcome of the assay. Each run is a complete experiment performed on replicate wells of cells plated from a common pool of cells at the same time. Independent run : A separate, independent experiment that evaluates chemical action on the biological outcome of the assay, using cells from a different pool, freshly diluted chemicals, conducted on different days or on the same day by different staff. SD : Standard deviation. Sensitivity : The proportion of all positive/active substances that are correctly classified by the assay. It is a measure of accuracy for an assay that produces categorical results, and is an important consideration in assessing the relevance of an assay (1). Specificity : The proportion of all negative/inactive substances that are correctly classified by the test. It is a measure of accuracy for an assay that produces categorical results, and is an important consideration in assessing the relevance of an assay (1). Stable transfection : When DNA is transfected into cultured cells in such a way that it is stably integrated into the cells genome, resulting in the stable expression of transfected genes. Clones of stably transfected cells are selected by stable markers (e.g. resistance to G418). STTA Assay : Stably Transfected Transactivation Assay, the ERα transcriptional activation assay using the HeLa 9903 Cell Line. Study : The full range of experimental work performed to evaluate a single, specific substance using a specific assay. A study comprises all steps including tests of dilution of test substance in the test media, preliminary range finding runs, all necessary comprehensive runs, data analyses, quality assurance, cytotoxicity assessments, etc. Completion of a study allows the classification of the test chemical activity on the toxicity target (i.e. active, inactive or inconclusive) that is evaluated by the assay used and an estimate of potency relative to the positive reference chemical. Substance : Under REACH (61), a substance is defined as a chemical element and its compounds in the natural state or obtained by any manufacturing process, including any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing its composition. A very similar definition is used in the context of the UN GHS (1). TA (Transactivation) : The initiation of mRNA synthesis in response to a specific chemical signal, such as a binding of an estrogen to the estrogen receptor Assay : Within the context of this test method, an assay is one of the methodologies accepted as valid in meeting the outlined performance criteria. Components of assay include, for example, the specific cell line with associated growth conditions, specific media in which the test is conducted, plate set up conditions, arrangement and dilutions of test chemicals along with any other required quality control measures and associated data evaluation steps. Test chemical : Any substance or mixture tested using this test method. Transcription : mRNA synthesis UVCB : Chemical Substances of Unknown or Variable Composition, Complex Reaction Products and Biological Materials Validated test method : An assay for which validation studies have been completed to determine the relevance (including accuracy) and reliability for a specific purpose. It is important to note that a validated test method may not have sufficient performance in terms of accuracy and reliability to be found acceptable for the proposed purpose (1). Validation : The process by which the reliability and relevance of a particular approach, method, assay, process or assessment is established for a defined purpose (1). VC (Vehicle control) : The solvent that is used to dissolve test and control chemicals is tested solely as vehicle without dissolved chemical. VM7 : An immortalised adenocarcinoma cell that endogenously express estrogen receptor. VM7Luc4E2 : The VM7Luc4E2 cell line was derived from VM7 immortalised human-derived adenocarcinoma cells that endogenously express both forms of the estrogen receptor (ERα and ERβ) and have been stably transfected with the plasmid pGudLuc7.ERE. This plasmid contains four copies of a synthetic oligonucleotide containing the estrogen response element upstream of the mouse mammary tumor viral (MMTV) promoter and the firefly luciferase gene. Weak positive control : A weakly active substance selected from the reference chemicals list that is included in all tests to help ensure proper functioning of the assay. Appendix 2 STABLY TRANSFECTED HUMAN ESTROGEN RECEPTOR-Α TRANSACTIVATION ASSAY FOR DETECTION OF ESTROGENIC AGONIST AND ANTAGONIST ACTIVITY OF CHEMICALS USING THE HERΑ-HELA-9903 CELL LINE INITIAL CONSIDERATIONS AND LIMITATIONS (SEE ALSO GENERAL INTRODUCTION)
PRINCIPLE OF THE ASSAY (SEE ALSO GENERAL INTRODUCTION)
PROCEDURE Cell Lines
Stability of the cell line
Cell Culture and Plating Conditions
Acceptability criteria Positive and negative reference standards for ER agonist assay
Table 1 Acceptable range values of the four reference standards for the ER agonist assay
Positive and negative reference standards for ER antagonist assay
Table 2 Criteria and acceptable range values of the two reference standards for the ER antagonist assay
Positive and Vehicle Controls
Quality criteria for ER agonist assay
Quality criteria for ER antagonist assay
Vehicle
Preparation of Test Chemicals
Solubility and Cytotoxicity: Considerations for Range Finding.
Chemical Exposure and Assay Plate Organisation
Step-1: Each test chemical should be serially diluted in DMSO, or appropriate solvent, and added to the wells of a microtitre plate to achieve final serial concentrations as determined by the preliminary range finding test (typically in a series of, for example 1 mM, 100 μM, 10 μM, 1μM, 100 nM, 10 nM, 1 nM, 100 pM, and 10 pM (10–3-10–11 M)) for triplicate testing. Step-2: Chemical dilution: First dilute 1,5 μl of the test chemical in the solvent to a volume of 500 μl of media. Step-3: Chemical exposure of the cells: Add 50 μl of dilution with media (prepared in Step-2) to an assay well containing 104 cells/100 μl/well. The recommended final volume of media required for each well is 150 μl. Test samples and reference standards can be assigned as shown in Table 3 and Table 4. Table 3 Example of plate concentration assignment of the reference standards in the assay plate in ER agonist assay
Table 4 Example of plate concentration assignment of test and plate control chemicals in the assay plate in ER agonist assay
Table 5 Example of plate concentration assignment of the reference standards in the assay plate in ER antagonist assay
Table 6 Example of plate concentration assignment of test and plate control chemicals in the assay plate in ER antagonist assay
Luciferase assay
ANALYSIS OF DATA ER agonist assay
Step 1. Calculate the mean value for the VC. Step 2. Subtract the mean value of the VC from each well value to normalise the data. Step 3. Calculate the mean for the normalised PC. Step 4. Divide the normalised value of each well in the plate by the mean value of the normalised PC (PC=100 %). The final value of each well is the relative transcriptional activity for that well compared to the PC response. Step 5. Calculate the mean value of the relative transcriptional activity for each concentration group of the test chemical. There are two dimensions to the response: the averaged transcriptional activity (response) and the concentration at which the response occurs (see following section). EC50, PC50 and PC10 induction considerations
ER antagonist assay
IC30 and IC50 induction considerations
Data Interpretation Criteria Table 7 Positive and negative decision criteria in ER agonist assay
Table 8 Positive and negative decision criteria in ER antagonist assay
TEST REPORT
LITERATURE
Appendix 2.1 FALSE POSITIVES: ASSESSMENT OF NON-RECEPTOR MEDIATED LUMINESCENCE SIGNALS
Data interpretation criteria Note: All wells should be treated with the same concentration of the vehicle.
Data analysis Check the performance standard. Check the CV between wells treated under the same conditions.
Appendix 2.2 PREPARATION OF SERUM TREATED WITH DEXTRAN COATED CHARCOAL (DCC)
Components
Materials
Equipment Autoclaved glass container (size should be adjusted as appropriate) General Laboratory Centrifuge (that can set temperature at 4 °C) Procedure
Appendix 3 VM7LUC ESTROGEN RECEPTOR TRANSACTIVATION ASSAY FOR IDENTIFYING ESTROGEN RECEPTOR AGONISTS AND ANTAGONISTS INITIAL CONSIDERATIONS AND LIMITATIONS (SEE ALSO GENERAL INTRODUCTION)
PRINCIPLE OF THE ASSAY (SEE ALSO GENERAL INTRODUCTION)
PROCEDURE Cell Line
Stability of the Cell Line
Cell Culture and Plating Conditions
Acceptability Criteria
Agonist Test Range Finder Test
Comprehensive Test It includes acceptability criteria from the agonist range finder test and the following:
Antagonist Test Range Finder Test
Comprehensive Test It includes acceptance criteria from the antagonist range finder test and the following:
Reference Standards, Positive, and Vehicle Controls Vehicle Control (Agonist and Antagonist Assays)
Reference Standard (Agonist Range Finder)
Reference Standard (Agonist Comprehensive)
Reference Standard (Antagonist Range Finder)
Reference Standard (Antagonist Comprehensive)
Weak Positive Control (Agonist)
Weak Positive Control (Antagonist)
E2 Control (Antagonist Assay Only)
Fold-Induction (Agonist)
Fold-Reduction (Antagonist)
Vehicle
Preparation of Test chemicals
Solubility and Cytotoxicity: Considerations for Range Finding
Test chemical Exposure and Assay Plate Organisation
Range Finder Tests
Figure 1 Agonist Range Finder Test 96-well Plate Layout Abbreviations: E2-1 to E2-4 = concentrations of the E2 reference standard (from high to low); TC1-1 to TC1-7 = concentrations (from high to low) of test chemical 1 (TC1); TC2-1 to TC2-7 = concentrations (from high to low) of test chemical 2 (TC2); TC3-1 to TC3-7 = concentrations (from high to low) of test chemical 3 (TC3); TC4-1 to TC4-7 = concentrations (from high to low) of test chemical 4 (TC4); TC5-1 to TC5-7 = concentrations (from high to low) of test chemical 5 (TC5); TC6-1 to TC6-7 = concentrations (from high to low) of test chemical 6 (TC6); VC = vehicle control (DMSO [1 % v/v EFM.]). Figure 2 Antagonist Range Finder Test 96-well Plate Layout Abbreviations: E2 = E2 control; Ral-1 to Ral-3 = concentrations of the Raloxifene/E2 reference standard (from high to low); TC1-1 to TC1-7 = concentrations (from high to low) of test chemical 1 (TC1); TC2-1 to TC2-7 = concentrations (from high to low) of test chemical 2 (TC2); TC3-1 to TC3-7 = concentrations (from high to low) of test chemical 3 (TC3); TC4-1 to TC4-7 = concentrations (from high to low) of test chemical 4 (TC4); TC5-1 to TC5-7 = concentrations (from high to low) of test chemical 5 (TC5); TC6-1 to TC6-7 = concentrations (from high to low) of test chemical 6 (TC6); VC = vehicle control (DMSO [1 % v/v EFM.]). Note: All test chemicals are tested in the presence of 9,18 × 10 11 M E2.
Comprehensive Tests
Figure 3 Agonist Comprehensive Test 96-well Plate Layout Abbreviations: TC1-1 to TC1-11 = concentrations (from high to low) of test chemical 1; TC2-1 to TC2-11 = concentrations (from high to low) of test chemical 2; E2-1 to E2-11 = concentrations of the E2 reference standard (from high to low); Meth = p,p’ methoxychlor weak positive control; VC = DMSO (1 % v/v) EFM vehicle control Figure 4 Antagonist Comprehensive Test 96-well Plate Layout Abbreviations: E2 = E2 control; Ral-1 to Ral-9 = concentrations of the Raloxifene/E2 reference standard (from high to low); Tam = Tamoxifen/E2 weak positive control; TC1-1 to TC1-11 = concentrations (from high to low) of test chemical 1 (TC1); TC2-1 to TC2-11 = concentrations (from high to low) of test chemical 2 (TC2); VC = vehicle control (DMSO [1 % v/v EFM.]). Note: As noted, all reference and test wells contain a fixed concentration of E2 (9.18 × 10-11 M)
Measure of Luminescence
ANALYSIS OF DATA EC50 /IC50 determination
Where: Y= response (i.e. RLUs); X= the logarithm of concentration; Bottom= the minimum response; Top= the maximum response; lg EC50 (or lg IC50)= the logarithm of X as the response midway between Top and Bottom; Hillslope= the steepness of the curve. The model calculates the best fit for the Top, Bottom, Hillslope, and IC50 and EC50 parameters. For the calculation of EC50 and IC50 values, appropriate statistical software should be used (e.g. Graphpad PrismR statistical software). Determination of Outliers
Collection and Adjustment of Luminometer Data for Range Finder Testing
Agonist
Antagonist
Collection and Adjustment of Luminometer Data for Comprehensive Testing
Agonist
Antagonist
Data Interpretation Criteria
Table 1 Positive and Negative Decision Criteria
Figure 5 Agonist Examples: Positive, Negative and Inadequate Data Dashed line indicates 20 % of E2 response, 2000 adjusted and normalised RLUs. Figure 6 Antagonist Examples: Positive, Negative, and Inadequate Data Dashed line indicates 80 % of Ral/E2 response, 8000 adjusted and normalised RLUs. Solid line indicates 1,00 10-5 M. For a response to be considered positive, it should be below the 8000 RLU line, and at concentrations less than 1,00 10-5 M. Asterisked concentrations in the meso-hexestrol graph indicate viability scores of "2" or greater. The test results for meso-hexestrol are considered inadequate data because the only response that is below 8,000 RLU occurs at 1,00 10-5 M.
TEST REPORT
LITERATURE
Appendix 4 STABLY TRANSFECTED HUMAN ESTROGEN RECEPTOR-Α TRANSACTIVATION ASSAY FOR DETECTION OF ESTROGENIC AGONIST AND ANTAGONIST ACTIVITY OF CHEMICALS USING THE ERΑ CALUX CELL LINE INITIAL CONSIDERATIONS AND LIMITATIONS (SEE ALSO GENERAL INTRODUCTION)
PRINCIPLE OF THE ASSAY (SEE ALSO GENERAL INTRODUCTION)
PROCEDURE Cell lines
Stability of the cell line
Cell Culture and plating conditions
Acceptability criteria
Table 1 Concentrations of reference standard, positive control (PC) and negative control (NC) for the agonistic CALUX bioassay
Table 2 Concentrations of reference standard, positive control (PC) and negative control (NC) for the antagonistic CALUX bioassay
Table 3 Acceptance criteria for the agonistic ERα CALUX bioassay
Appr.: approximative; PC: positive control; NC: negative control; SC: test chemical solvent control; C0: reference standard solvent control; SD: standard deviation; LDH: lactate dehydrogenase Table 4 Acceptance criteria for the antagonistic ERα CALUX bioassay
Appr.: approximative; PC: positive control; NC: negative control; VC: vehicle control (solvent control without fixed concentration of agonist reference standard); SC: test chemical solvent control; C0: reference standard solvent control; SD: standard deviation; LDH: lactate dehydrogenase Solvent/vehicle control, reference standards, positive controls, negative controls
Solvent control
Vehicle control (antagonism)
Reference standards
Positive control
Negative control
Demonstration of laboratory proficiency (see paragraph 14 and Tables 3 and 4 in «ER TA ASSAY COMPONENTS» of this test method) Vehicle
Preparation of reference standards, positive controls, negative controls and test chemicals
Solubility, cytotoxicity and range finding.
Test chemical exposure and assay plate organisation
Figure 1 Plate layout of the 96-well microtiter plates for prescreening and assessment of agonistic effect. C0 = reference standard solvent. C(1-8) = series of dilutions (1-8, low-to-high concentrations) of reference standard. PC = positive control. NC = negative control. TCx-(1-8) = dilutions (1-8, low-to-high concentrations) of test chemical for the prescreen run and assessment of agonistic effect of test chemical x. SC = solvent control of the test chemical (optimally the same solvent as in C0, but possibly from another batch). Grey cells: = Outer wells, filled up with 200 μl of PBS. Figure 2 Plate layout of the 96-well microtiter plates for antagonistic prescreening and assessment of antagonistic effect. C0 = reference standard solvent. C(1-8) = series of dilutions (1-8, low-to-high concentrations) of reference standard. NC = negative control. PC = positive control. TCx-(1-8) = dilutions (1-8, low-to-high concentrations) of test chemical for the prescreen run and assessment of agonistic effect of test chemical x. SC = solvent control of the test chemical (optimally the same solvent as in C0, but possibly from another batch). VC = vehicle control (solvent control without fixed concentration of agonist reference standard 17β-estradiol). Grey cells: = Outer wells, filled up with 200 μl of PBS. Note: all inner-wells, except for the vehicle control wells (VC), also contain a fixed concentration of agonist reference standard 17β-estradiol (3.0*10-12 M) Measurement of luminescence
Prescreen run
Selection of concentrations for assessment of agonistic effects
Selection of concentrations for assessment of antagonistic effects
Comprehensive runs
Table 5 Concentration and dilutions of reference standards, controls and test chemicals used for agonist testing
Table 6 Concentration and dilutions of reference standards, controls and test chemicals used for antagonist testing
Collection of data and data analysis
Agonism
For test chemicals, a full dose-response curve may not always be achieved due to e.g. cytotoxicity or solubility problems. Hence, the EC50, EC10 and PC50 cannot be determined. In such case, only the PC10 and TCmax can be determined. Antagonism
Figure 3 Overview of parameters determined in the agonist assay EC10 = concentration of a substance at which 10 % of its maximum response is observed. EC50 = concentration of a substance at which 50 % of its maximum response is observed. PC10 = concentration of a test chemical at which its response is equal to the EC10 of the reference standard. PC50 = concentration of a test chemical at which its response is equal to the EC50 of the reference standard. TCxmax = maximum relative induction of test chemical. Figure 4 Overview of parameters determined in the antagonist assay IC20 = concentration of a substance at which 80 % of its maximum response is observed (20 % inhibition). IC50 = concentration of a substance at which 50 % of its maximum response is observed (50 % inhibition). PC80 = concentration of a test chemical at which its response is equal to the IC20 of the reference standard. PC50 = concentration of a test chemical at which its response is equal to the IC50 of the reference standard. TCxmin = minimum relative induction of test chemical. For test chemicals, a full dose-response curve may not always be achieved due to e.g. cytotoxicity or solubility problems. Hence, the IC50, IC20 and PC50 cannot be determined. In such case, only the PC20 and TCmin can be determined.
Data interpretation criteria
TEST REPORT
LITERATURE
Appendix 4.1 VISUAL INSPECTION OF CELL VIABILITY
B.67 IN VITRO MAMMALIAN CELL GENE MUTATION TESTS USING THE THYMIDINE KINASE GENE INTRODUCTION
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DESCRIPTION OF THE METHOD Preparations Cells
Media and culture conditions
Preparation of cultures
Metabolic activation
Test chemical preparations
TEST CONDITIONS Solvents
MEASURING CYTOTOXICITY AND CHOOSING TREATMENT CONCENTRATIONS
Controls
Table 1 Reference substances recommended for assessing laboratory proficiency and for selection of positive controls
PROCEDURE Treatment with test chemical
Phenotypic expression time and measurement of cytotoxicity and mutant frequency
Mutant Colony characterisation
Proficiency of the laboratory
Historical control data
DATA AND REPORTING Presentation of the results
Acceptability Criteria
Acceptability criteria for negative and positive controls
Evaluation and interpretation of results
MLA
TK6
For both the MLA and TK6:
TEST REPORT
LITERATURE
Appendix 1 DEFINITIONS Aneugen : Any chemical or process that, by interacting with the components of the mitotic and meiotic cell division cycle, leads to aneuploidy in cells or organisms. Aneuploidy : Any deviation from the normal diploid (or haploid) number of chromosomes by a single chromosome or more than one, but not by entire set(s) of chromosomes (polyploidy). Base-pair-substitution mutagens : Chemicals that cause substitution of base pairs in the DNA. Chemical : A substance or a mixture. Cloning efficiency : The percentage of cells plated at a low density that are able to grow into a colony that can be counted. Clastogen : Any chemical or process which causes structural chromosomal aberrations in populations of cells or organisms. Cytotoxicity : For the assays covered in this test method, cytotoxicity is identified as a reduction in relative total growth (RTG) or relative survival (RS) for the MLA and TK6, respectively. Forward mutation : A gene mutation from the parental type to the mutant form which gives rise to an alteration or a loss of the enzymatic activity or the function of the encoded protein. Frameshift mutagens : Chemicals which cause the addition or deletion of single or multiple base pairs in the DNA molecule. Genotoxic : Ageneral term encompassing all types of DNA or chromosomal damage, including DNA breakage, adducts, rearrangements, mutations, chromosome aberrations, and aneuploidy. Not all types of genotoxic effects result in mutations or stable chromosomal damage. Mitotic recombination : During mitosis, recombination between homologous chromatids possibly resulting in the induction of DNA double strand breaks or in a loss of heterozygosity. Mutagenic : Produces a heritable change of DNA base-pair sequences(s) in genes or of the structure of chromosomes (chromosome aberrations). Mutant frequency (MF) : The number of mutant cells observed divided by the number of viable cells. Phenotypic expression time : The time after treatment during which the genetic alteration is fixed within the genome and any pre-existing gene products are depleted to the point that the phenotypic trait is altered. Relative survival (RS) : RS is used as the measure of treatment-related cytotoxicity in the TK6. It is the relative cloning efficiency (CE) of cells plated immediately after the cell treatment adjusted by any loss of cells during treatment as compared with the cloning efficiency of the negative control. Relative suspension growth (RSG) : For the MLA, the relative total two day suspension growth of the test culture compared to the total two-day suspension growth of the negative/solvent control (Clive and Spector, 1975). The RSG should include the relative growth of the test culture compared to the negative/solvent control during the treatment period. Relative total growth (RTG) : RTG is used as the measure of treatment-related cytotoxicity in the MLA. It is a measure of relative (to the vehicle control) growth of test cultures during the treatment, two-day expression and mutant selection cloning phases of the test. The RSG of each test culture is multiplied by the relative cloning efficiency of the test culture at the time of mutant selection and expressed relative to the cloning efficiency of the negative/solvent control (Clive and Spector, 1975). S9 liver fractions : Supernatant of liver homogenate after 9 000g centrifugation, i.e. raw liver extract S9 mix : Mix of the liver S9 fraction and cofactors necessary for metabolic enzyme activity. Suspension growth (SG) : The fold-increase in the number of cells over the course of the treatment and expression phases of the MLA. The SG is calculated by multiplying the fold-increase on day 1 by the fold-increase on day 2 for the short (3 or 4 hr) treatment. If a 24 hr treatment is used the SG is the fold-increase during the 24 hr treatment multiplied by the fold increases on expression days 1 and 2. Solvent control : General term to define the control cultures receiving the solvent alone used to dissolve the test chemical. Test chemical : Any substance or mixture tested using this test method. Untreated controls : Untreated controls are cultures that receive no treatment (i.e. neither test chemical nor solvent) but are processed the same way as the cultures receiving the test chemical. Appendix 2 FORMULAS Cytotoxicity For both versions (agar and microwell) of the MLA Cytotoxicity is defined as the Relative Total Growth (RTG) which includes the Relative Suspension Growth (RSG) during the 2 day expression period and the Relative Cloning Efficiency (RCE) obtained at the time of mutant selection. RTG, RSG and RCE are all expressed as a percentage. Calculation of RSG: Suspension Growth one (SG1) is the growth rate between day 0 and day 1 (cell concentration at day 1 / cell concentration at day 0) and Suspension Growth two (SG2) is the growth rate between day 1 and day 2 (cell concentration at day 2 / cell concentration at day 1). The RSG is the total SG (SG1 × SG2) for the treated culture compared to the untreated/solvent control. That is: RSG = [SG1(test) × SG2(test)] / [SG1(control) × SG2(control)] The SG1 should be calculated from the initial cell concentration used at the beginning of cell treatment. This accounts for any differential cytotoxicity that occurs in the test culture(s) during the cell treatment. RCE is the relative cloning efficiency of the test culture compared to the relative cloning efficiency of the untreated/solvent control obtained at the time of mutant selection. Relative Total Growth (RTG): RTG=RSG × RCE TK6 Relative Survival (RS): Cytotoxicity is evaluated by relative survival, i.e. cloning efficiency (CE) of cells plated immediately after treatment adjusted by any loss of cells during treatment as compared with cloning efficiency in the negative controls (assigned a survival of 100 %). The adjustment for cell loss during treatment can be calculated as:
The RS for a culture treated by a test chemical is calculated as:
Mutant frequency for both the MLA and TK6 Mutant frequency (MF) is the cloning efficiency of mutant colonies in selective medium (CEM) adjusted by the cloning efficiency in non-selective medium at the time of mutant selection (CEV). That is, MF=CEM/CEV. The calculation of these two cloning efficiencies is described below for the agar and microwell cloning methods. MLA Agar Version: In the soft agar version of the MLA, the number of colonies on the mutant selection plate (CM) and number of colonies on the unselected or cloning efficiency (viable count) plate (CV) are obtained by directly counting the clones. When 600 cells are plated for cloning efficiency (CE) for the mutant selection (CEM) plates and the unselected or cloning efficiency (viable count) plates (CEV) and 3 × 106 cells are used for mutant selection, CEM = CM / (3 × 106) = (CM / 3) × 10-6 CEV = CV / 600 MLA and TK6 Microwell Version: In the microwell version of the MLA, CM and CV are determined as the product of the total number of microwells (TW) and the probable number of colonies per well (P) on microwell plates. CM = PM × TWM CV = PV × TWV From the zero term of the Poisson distribution (Furth et al., 1981), the P is given by P = -ln (EW / TW) Where, EW is empty wells and TW is total wells. Therefore, CEM = CM / TM = (PM × TWM) / TM CEV = CV / TV = (PV × TWV) / TV For the microwell version of the MLA, small and large colony mutant frequencies will be calculated in an identical manner, using the relevant number of empty wells for small and large colonies. For TK6, small and large colony mutant frequencies are based on the early appearing and late appearing mutants. B.68 SHORT TIME EXPOSURE IN VITRO TEST METHOD FOR IDENTIFYING i) CHEMICALS INDUCING SERIOUS EYE DAMAGE AND ii) CHEMICALS NOT REQUIRING CLASSIFICATION FOR EYE IRRITATION OR SERIOUS EYE DAMAGE INTRODUCTION
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE Preparation of the Cellular Monolayer
Application of the Test Chemicals and Control Substances
Cell Viability Measurement
Interpretation of Results and Prediction Model
Table 2 Prediction model of the STE test method
Acceptance Criteria
DATA AND REPORTING Data
Test Report
LITERATURE
Appendix DEFINITIONS Accuracy : The closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of relevance. The term is often used interchangeably with concordance to mean the proportion of correct outcomes of a test method (13). Benchmark substance : A substance used as a standard for comparison to a test chemical. A benchmark substance should have the following properties; (i) a consistent and reliable source(s); (ii) structural and functional similarity to the class of substances being tested; (iii) known physical/chemical characteristics; (iv) supporting data on known effects, and (v) known potency in the range of the desired response. Bottom-Up Approach : A step-wise approach used for a test chemical suspected of not requiring classification for eye irritation or serious eye damage, which starts with the determination of chemicals not requiring classification (negative outcome) from other chemicals (positive outcome) Chemical : A substance or mixture. Eye irritation : Production of change in the eye following the application of a test chemical to the anterior surface of the eye, which are fully reversible within 21 days of application. Interchangeable with “reversible effects on the eye” and with UN GHS/CLP Category 2 False negative rate : The proportion of all positive chemicals falsely identified by a test method as negative. It is one indicator of test method performance. False positive rate : The proportion of all negative chemicals that are falsely identified by a test method as positive. It is one indicator of test method performance. Hazard : Inherent property of an agent or situation having the potential to cause adverse effects when an organism, system or (sub) population is exposed to that agent. Medium control : An untreated replicate containing all components of a test system. This sample is processed with test chemical-treated samples and other control samples to determine whether the solvent interacts with the test system. Mixture : A mixture or a solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). MTT : 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide; Thiazolyl blue tetrazolium bromide. Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. OD : Optical Density. Positive control : A replicate containing all components of a test system and treated with a substance known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Relevance : Description of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (10). Reliability : Measures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility and intra-laboratory repeatability (13). Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (10). Serious eye damage : Production of tissue damage in the eye, or serious physical decay of vision, following application of a test chemical to the anterior surface of the eye, which is not fully reversible within 21 days of application. Interchangeable with “irreversible effects on the eye” and with UN GHS/CLP Category 1. Solvent/vehicle control : An untreated sample containing all components of a test system, including the solvent or vehicle that is processed with the test chemical-treated and other control samples to establish the baseline response for the samples treated with the test chemical dissolved in the same solvent or vehicle. When tested with a concurrent medium control, this sample also demonstrates whether the solvent or vehicle interacts with the test system. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (13). Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Surfactant : Also called surface-active agent, this is a chemical such as a detergent, that can reduce the surface tension of a liquid and thus allow it to foam or penetrate solids; it is also known as a wetting agent. Test chemical : Any substance or mixture tested using this Test Method. Tiered testing strategy : A stepwise testing strategy where all existing information on a test chemical is reviewed, in a specified order, using a weight of evidence process at each tier to determine if sufficient information is available for a hazard classification decision, prior to progression to the next tier. If the irritancy potential of a test chemical can be assigned based on the existing information, no additional testing is required. If the irritancy potential of a test chemical cannot be assigned based on the existing information, a step-wise sequential animal testing procedure is performed until an unequivocal classification can be made. Top-Down Approach : step-wise approach used for a test chemical suspected of causing serious eye damage, which starts with the determination of chemicals inducing serious eye damage (positive outcome) from other chemicals (negative outcome). United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) : A system proposing the classification of chemicals (substances and mixtures) according to standardized types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1). UN GHS/CLP Category 1 : See “Serious eye damage”. UN GHS/CLP Category 2 : See “Eye irritation”. UN GHS/CLP No Category : Chemicals that are not classified as UN GHS/CLP Category 1 or 2 (or UN GHS Category 2A or 2B). UVCB : substances of unknown or variable composition, complex reaction products or biological materials. B.69 RECONSTRUCTED HUMAN CORNEA-LIKE EPITHELIUM (RhCE) TEST METHOD FOR IDENTIFYING CHEMICALS NOT REQUIRING CLASSIFICATION AND LABELLING FOR EYE IRRITATION OR SERIOUS EYE DAMAGE INTRODUCTION
DEFINITIONS
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
RHCE TEST METHOD COMPONENTS General conditions
Functional conditions Viability
Table 2 Acceptability ranges for negative control OD values (for the test users)
Barrier function
Morphology
Reproducibility
Quality control (QC)
Table 3 QC batch release criterion
Application of the Test Chemical and Control Substances
Tissue Viability Measurements
Acceptance Criteria
Interpretation of Results and Prediction Model
DATA AND REPORTING Data
Test Report
LITERATURE
Appendix 1 DEFINITIONS Accuracy : The closeness of agreement between test method results and accepted reference values. It is a measure of test method performance and one aspect of “relevance.” The term is often used interchangeably with “concordance”, to mean the proportion of correct outcomes of a test method (18). Benchmark chemical : A chemical used as a standard for comparison to a test chemical. A benchmark chemical should have the following properties: (i) consistent and reliable source(s) for its identification and characterisation; (ii) structural, functional and/or chemical or product class similarity to the chemical(s) being tested; (iii) known physicochemical characteristics; (iv) supporting data on known effects; and (v) known potency in the range of the desired response. Bottom-Up approach : Step-wise approach used for a test chemical suspected of not requiring classification and labelling for eye irritation or serious eye damage, which starts with the determination of chemicals not requiring classification and labelling (negative outcome) from other chemicals (positive outcome). Chemical : A substance or mixture. Concordance : See "Accuracy". Cornea : The transparent part of the front of the eyeball that covers the iris and pupil and admits light to the interior. CV : Coefficient of Variation. Dev : Deviation. EIT : Eye Irritation Test. EURL ECVAM : European Union Reference Laboratory for Alternatives to Animal Testing. Eye irritation : Production of changes in the eye following the application of a test chemical to the anterior surface of the eye, which are fully reversible within 21 days of application. Interchangeable with “Reversible effects on the eye” and with “UN GHS/CLP Category 2”. ET50 : Exposure time required to reduce tissue viability by 50 % upon application of a benchmark chemical at a specified, fixed concentration. False negative rate : The proportion of all positive substances falsely identified by a test method as negative. It is one indicator of test method performance. False positive rate : The proportion of all negative substances that are falsely identified by a test method as positive. It is one indicator of test method performance. Hazard : Inherent property of an agent or situation having the potential to cause adverse effects when an organism, system or (sub) population is exposed to that agent. HCE : SkinEthic™ Human Corneal Epithelium. HPLC : High Performance Liquid Chromatography. IC50 : Concentration at which a benchmark chemical reduces the viability of the tissues by 50 % following a fixed exposure time (e.g. 30 minutes treatment with SDS). Infinite dose : Amount of test chemical applied to the RhCE tissue construct exceeding the amount required to completely and uniformly cover the epithelial surface. Irreversible effects on the eye : See “Serious eye damage”. LLOQ : Lower Limit of Quantification. LogP : Logarithm of the octanol-water partitioning coefficient Mixture : A mixture or a solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. MTT : 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide; Thiazolyl blue tetrazolium bromide. Negative control : A sample containing all components of a test system and treated with a substance known not to induce a positive response in the test system. This sample is processed with test chemical-treated samples and other control samples and is used to determine 100 % tissue viability. Not Classified : Chemicals that are not classified for Eye irritation (UN GHS/CLP Category 2, UN GHS Category 2A or 2B) or Serious eye damage (UN GHS/CLP Category 1). Interchangeable with “UN GHS/CLP No Category”. NSCkilled : Non-Specific Colour in killed tissues. NSCliving : Non-Specific Colour in living tissues. NSMTT : Non-Specific MTT reduction. OD : Optical Density. Performance standards : Standards, based on a validated test method which was considered scientifically valid, that provide a basis for evaluating the comparability of a proposed test method that is mechanistically and functionally similar. Included are: (i) essential test method components; (ii) a minimum list of Reference Chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (iii) the comparable levels of accuracy and reliability, based on what was obtained for the validated test method, that the proposed test method should demonstrate when evaluated using the minimum list of Reference Chemicals (18). Positive control : A sample containing all components of a test system and treated with a substance known to induce a positive response in the test system. This sample is processed with test chemical-treated samples and other control samples. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Relevance : Description of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test method (18). Reliability : Measures of the extent that a test method can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility and intra-laboratory repeatability (18). Replacement test : A test which is designed to substitute for a test that is in routine use and accepted for hazard identification and/or risk assessment, and which has been determined to provide equivalent or improved protection of human or animal health or the environment, as applicable, compared to the accepted test, for all possible testing situations and chemicals (18). Reproducibility : The agreement among results obtained from repeated testing of the same test chemical using the same test protocol (See "Reliability") (18). Reversible effects on the eye : See “Eye irritation”. RhCE : Reconstructed human Cornea-like Epithelium. Run : A run consists of one or more test chemicals tested concurrently with a negative control and with a positive control. SD : Standard Deviation. Sensitivity : The proportion of all positive/active test chemicals that are correctly classified by the test. It is a measure of accuracy for a test method that produces categorical results, and is an important consideration in assessing the relevance of a test method (18). Serious eye damage : Production of tissue damage in the eye, or serious physical decay of vision, following application of a test substance to the anterior surface of the eye, which is not fully reversible within 21 days of application. Interchangeable with “Irreversible effects on the eye” and with “UN GHS and CLP Category 1”. Standard Operating Procedures (SOP) : Formal, written procedures that describe in detail how specific routine, and test-specific, laboratory operations should be performed. They are required by GLP. Specificity : The proportion of all negative/inactive test chemicals that are correctly classified by the test. It is a measure of accuracy for a test method that produces categorical results and is an important consideration in assessing the relevance of a test method (18). Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Test : A single test chemical concurrently tested in a minimum of two tissue replicates as defined in the corresponding SOP. Tissue viability : Parameter measuring total activity of a cell population in a reconstructed tissue as their ability to reduce the vital dye MTT, which, depending on the endpoint measured and the test design used, correlates with the total number and/or vitality of living cells. Top-Down approach : Step-wise approach used for a chemical suspected of causing serious eye damage, which starts with the determination of chemicals inducing serious eye damage (positive outcome) from other chemicals (negative outcome). Test chemical : Any substance or mixture tested using this test method. Tiered testing strategy : A stepwise testing strategy, which uses test methods in a sequential manner. All existing information on a test chemical is reviewed at each tier, using a weight-of-evidence process, to determine if sufficient information is available for a hazard classification decision, prior to progression to the next tier in the strategy. If the hazard potential/potency of a test chemical can be assigned based on the existing information at a given tier, no additional testing is required (18). ULOQ : Upper Limit of Quantification. United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) : A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (1). UN GHS and CLP Category 1 : See “Serious eye damage”. UN GHS and CLP Category 2 : See “Eye irritation”. UN GHS and CLP No Category : Chemicals that do not meet the requirements for classification as UN GHS/CLP Category 1 or 2 (or UN GHS Category 2A or 2B). Interchangeable with “Not Classified”. UPLC : Ultra-High Performance Liquid Chromatography. UVCB : substances of unknown or variable composition, complex reaction products or biological materials. Valid test method : A test method considered to have sufficient relevance and reliability for a specific purpose and which is based on scientifically sound principles. A test method is never valid in an absolute sense, but only in relation to a defined purpose (18). Validated test method : A test method for which validation studies have been completed to determine the relevance (including accuracy) and reliability for a specific purpose. It is important to note that a validated test method may not have sufficient performance in terms of accuracy and reliability to be found acceptable for the proposed purpose (18). VRM : Validated Reference Method. VRM1 : EpiOcular™ EIT is referred as the Validated Reference Method 1. VRM2 : SkinEthic™ HCE EIT is referred to as the Validated Reference Method 2. Weight-of-evidence : The process of considering the strengths and weaknesses of various pieces of information in reaching and supporting a conclusion concerning the hazard potential of a test substance. Appendix 2 MAIN TEST COMPONENTS OF THE RHCE TESTS VALIDATED FOR IDENTIFYING CHEMICALS NOT REQUIRING CLASSIFICATION AND LABELLING FOR EYE IRRITATION OR SEERIOUS EYE DAMAGE
Appendix 3 ILLUSTRATIVE FLOWCHART PROVIDING GUIDANCE ON HOW TO IDENTIFY AND HANDLE DIRECT MTT-REDUCERS AND/OR COLOUR INTERFERING CHEMICALS, BASED ON THE VRM1 SOP Appendix 4 ILLUSTRATIVE FLOWCHART PROVIDING GUIDANCE ON HOW TO IDENTIFY AND HANDLE DIRECT MTT-REDUCERS AND/OR COLOUR INTERFERING CHEMICALS, BASED ON THE VRM2 SOP Appendix 5 KEY PARAMETERS AND ACCEPTANCE CRITERIA FOR QUALIFICATION OF AN HPLC/UPLC-SPECTROPHOTOMETRY SYSTEM FOR MEASUREMENT OF MTT FORMAZAN EXTRACTED FROM RHCE TISSUE CONSTRUCTS
B.70 HUMAN RECOMBINANT ESTROGEN RECEPTOR (hrER) IN VITRO ASSAYS TO DETECT CHEMICALS WITH ER BINDING AFFINITY GENERAL INTRODUCTION OECD Performance-Based Test Guideline
Background and principles of the assays included in this test method
Scope and limitations related to the receptor binding assays
hrER BINDING ASSAY COMPONENTS Essential Assay Components
Controls
Standard Quality Control Procedures
Demonstration of Laboratory Proficiency
Solubility Testing and Concentration Range Finding for Test Chemicals
Test Run Acceptability Criteria
Analysis of data
General Data Interpretation Criteria
Test Report
LITERATURE
Appendix 1 DEFINITIONS AND ABBREVIATIONS 10 % Rule: Option to exclude from the analyses data points where the mean of the replicates for the percent [3H]17β-estradiol specific bound is 10 % or more above that observed for the mean value at a lower concentration (see Appendix 4). Acceptability criteria: Minimum standards for the performance of experimental controls and reference standards. All acceptability criteria should be met for an experiment to be considered valid. Accuracy (concordance): The closeness of agreement between assay results and an accepted reference values. It is a measure of assay performance and one aspect of relevance. The term is often used interchangeably with “concordance” to mean the proportion of correct outcomes of an assay (1). CF: The OECD Conceptual Framework for the Testing and Evaluation of Endocrine Disrupters. Chemical: A substance or a mixture. CV: Coefficient of variation E2: 17β-estradiol ED: Endocrine disruption hERα: Human estrogen receptor alpha ER: Estrogen receptor Estrogenic activity: The capability of a chemical to mimic 17β-estradiol in its ability to bind estrogen receptors. Binding to the hERα can be detected with this test method. IC50: The half maximal effective concentration of an inhibitory test chemical. ICCVAM: The Interagency Coordinating Committee on the Validation of Alternative Methods. Inter-laboratory reproducibility: A measure of the extent to which different qualified laboratories, using the same protocol and testing the same substances, can produce qualitatively and quantitatively similar results. Interlaboratory reproducibility is determined during the prevalidation and validation processes, and indicates the extent to which an assay can be successfully transferred between laboratories, also referred to as between-laboratory reproducibility (1). Intra-laboratory reproducibility: A determination of the extent that qualified people within the same laboratory can successfully replicate results using a specific protocol at different times. Also referred to as “within-laboratory reproducibility” (1). LEC: Lowest effective concentration is the lowest concentration of test chemical that produces a response (i.e. the lowest test chemical concentration at which the fold induction is statistically different from the concurrent vehicle control). Me-too test: A colloquial expression for an assay that is structurally and functionally similar to a validated and accepted reference test method. Interchangeably used with similar test method PBTG: Performance-Based Test Guideline Performance standards: Standards, based on a validated test method, that provide a basis for evaluating the comparability of a proposed assay that is mechanistically and functionally similar. Included are (1) essential assay components; (2) a minimum list of reference chemicals selected from among the chemicals used to demonstrate the acceptable performance of the validated test method; and (3) the comparable levels of accuracy and reliability, based on what was obtained for the validated test method, that the proposed assay should demonstrate when evaluated using the minimum list of reference chemicals (1). Proficiency substances: A subset of the Reference substances included in the Performance Standards that can be used by laboratories to demonstrate technical competence with a standardised assay. Selection criteria for these substances typically include that they represent the range of responses, are commercially available, and have high quality reference data available. Proficiency: The demonstrated ability to properly conduct an assay prior to testing unknown substances. Reference estrogen: 17ß-estradiol (E2, CAS 50-28-2). Reference test methods: The assays upon which PBTG 493 is based. RBA: Relative Binding Affinity. The RBA of a substance is calculated as a percent of the log (IC50) for the substance relative to the log (IC50) for 17β-estradiol Relevance: Description of relationship of an assay to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the assay correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of an assay (1). Reliability: Measure of the extent that an assay can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility. SD: Standard deviation. Test chemical: Any substance or mixture tested using this test method. Validated test method: An assay for which validation studies have been completed to determine the relevance (including accuracy) and reliability for a specific purpose. It is important to note that a validated test method may not have sufficient performance in terms of accuracy and reliability to be found acceptable for the proposed purpose (1). Validation: The process by which the reliability and relevance of a particular approach, method, assay, process or assessment is established for a defined purpose (1). Appendix 2 THE FREYBERGER-WILSON IN VITRO ESTROGEN RECEPTOR (ERα) SATURATION AND COMPETITIVE BINDING ASSAYS USING FULL LENGTH RECOMBINANT ERα INITIAL CONSIDERATIONS AND LIMITATIONS (SEE ALSO GENERAL INTRODUCTION)
PRINCIPLES OF THE ASSAY (SEE ALSO GENERAL INTRODUCTION)
PROCEDURE Demonstration of Acceptable hrERα Protein Performance
Table 1 Performance criteria developed for the reference estrogen and weak binder, FW hrER Binding Assay
Demonstration of laboratory proficiency
Determination of Receptor (hrERα) Concentration
Saturation assay
Preparation of [3H]-17β-estradiol and unlabelled 17β-estradiol solutions
Table 2 Saturation Binding Assay Microtiter Plate Layout
Measurement of [3H]-17β-Estradiol bound to hrERα
Table 3 Saturation Binding Assay Microtiter Plate Layout, Radioactivity Measurement
Competitive binding assay
Controls
Solvent control:
Buffer control:
Strong binder (reference estrogen)
Weak binder
Non binder
hrERα concentration
[3H]-17β-estradiol
Test Chemicals
Assay plate organisation
Table 4 Competitive Binding Assay Microtiter Plate Layout, Full Concentration Curves for Reference Estrogen and Controls (Plate 1)
Table 5 Competitive Binding Assay Microtiter Plate Layout, Full Concentration Curves for Test Chemicals and Plate Controls
Completion of competitive binding assay
Table 6 Volume of Assay Components for hrER Competitive Binding Assay, Microtiter Plates
Acceptability criteria Saturation binding assay
Competitive binding assay
ANALYSIS OF DATA Saturation binding assay
Competitive binding assay
Data interpretation
Table 7 Criteria for assigning classification based upon competitive binding curve for a test chemical
Figure 1 Examples of test chemical classification using competitive binding curve
Table 8 Method for classification of test chemical using multiple runs within a laboratory
TEST REPORT
Appendix 2.1 LIST OF TERMS [3H]E2: 17β-Estradiol radiolabelled with tritium DCC: Dextran-coated charcoal E2: Unlabelled 17β-estradiol (inert) Assay buffer: 10 mM Tris, 10 mg Bovine Serum Albumin /ml, 2 mM DTT, 10 % glycerol, 0,2 mM leupeptin, pH 7.5 hrERα: Human recombinant estrogen receptor alpha Replicate: One of multiple wells that contain the same contents at the same concentrations and are assayed concurrently within a single run. In this protocol, each concentration of test chemical is tested in triplicate; that is, there are three replicates that are assayed simultaneously at each concentration of test chemical. Run: A complete set of concurrently-run microtiter plate assay wells that provides all the information necessary to characterise binding of a test chemical to the hrERα (viz., total [3H]-17β-estradiol added to the assay well, maximum binding of [3H]-17β-estradiol to the hrERα, nonspecific binding, and total binding at various concentrations of test chemical). A run could consist of as few as one assay well (i.e. replicate) per concentration, but since this protocol requires assaying in triplicate, one run consists of three assay wells per concentration. In addition, this protocol requires three independent (i.e. non-concurrent) runs per chemical. Appendix 2.2 TYPICAL [3H]-17Β-ESTRADIOL SATURATION ASSAY WITH THREE REPLICATE WELLS
Appendix 2.3 COMPETITIVE BINDING ASSAY WELL LAYOUT
Note that the "hot" wells are empty during incubation. The 40 μl are added only for scintillation counting.
Appendix 3 THE CHEMICAL EVALUATION AND RESEARCH INSTITUTE (CERI) IN VITRO ESTROGEN RECEPTOR BINDING ASSAY USING A HUMAN RECOMBINANT ERΑ LIGAND BINDING DOMAIN PROTEIN INITIAL CONSIDERATIONS AND LIMITATIONS (SEE ALSO GENERAL INTRODUCTION)
PRINCIPLES OF THE ASSAY (SEE ALSO GENERAL INTRODUCTION)
PROCEDURE Demonstration of Acceptable hrERα Protein Performance
Demonstration of laboratory proficiency
Determination of Receptor (hrERα) Concentration
Saturation assay
Measurement of [3H]-17β-Estradiol bound to hrERα
Competitive binding assay
Controls
Solvent control:
Buffer control:
Strong binder (reference estrogen)
Weak binder
Non binder
hrERα concentration
[3H]-17β-estradiol
Test Chemicals
Assay plate organisation
Table 4 Competitive Binding Assay Microtiter Plate Layout (97), (98) , Full Concentration Curves for Reference Estrogen and Controls (Plate 1)
Table 5 Competitive Binding Assay Microtiter Plate Layout, Additional Plates for Test Chemicals (TC) and Plate Controls
Completion of competitive binding assay
Acceptability criteria Saturation binding assay
Competitive binding assay
ANALYSIS OF DATA Saturation binding assay
Competitive binding assay
Data interpretation
Table 7 Criteria for assigning classification based upon competitive binding curve for a test chemical
Figure 1 Examples of test chemical classification using competitive binding curve.
Table 8 Method for classification of test chemical using multiple runs within a laboratory
TEST REPORT
Appendix 3.1 LIST OF TERMS [3H]E2 : 17β-Estradiol radiolabelled with tritium DCC : Dextran-coated charcoal E2 : Unlabelled 17β-estradiol (inert) Assay buffer : 10 mM Tris-HCl, pH 7.4, containing 1 mM EDTA, 1mM EGTA, 1 mM NaVO3, 10 % Glycerol, 0,2 mM Leupeptin, 1 mM Dithiothreitol and 10 mg/ml Bovine Serum Albumin hrERα : Human recombinant estrogen receptor alpha (ligand binding domain) Replicate : One of multiple wells that contain the same contents at the same concentrations and are assayed concurrently within a single run. In this protocol, each concentration of test chemical is tested in triplicate; that is, there are three replicates that are assayed simultaneously at each concentration of test chemical. Run : A complete set of concurrently-run microtiter plate assay wells that provides all the information necessary to characterise binding of a test chemical to the hrERα (viz., total [3H]-17β-estradiol added to the assay well, maximum binding of [3H]-17β-estradiol to the hrERα, nonspecific binding, and total binding at various concentrations of test chemical). A run could consist of as few as one assay well (i.e. replicate) per concentration, but since this protocol requires assaying in triplicate, one run consists of three assay wells per concentration. In addition, this protocol requires three independent (i.e. non-concurrent) runs per chemical. Appendix 3.2 COMPETITIVE BINDING ASSAY WELL LAYOUT
Appendix 4 CONSIDERATIONS FOR THE ANALYSIS OF DATA FROM THE HRER COMPETITIVE BINDING ASSAY
Data Analysis for the Reference Estrogen and Weak Binder (1)
Figure 1 Examples of the competitive binding curves for the reference estrogen and the control weak binder Data Analysis for Test Chemicals
Figure 2 Examples, Competitive Binding Curves with and without Use of the 10 % Rule
Figure 3 Examples, Competitive Binding Data Where Use of the 10 % Rule is Not Appropriate. References
B.71 IN VITRO SKIN SENSITISATION ASSAYS ADDRESSING THE KEY EVENT ON ACTIVATION OF DENDRITIC CELLS ON THE ADVERSE OUTCOME PATHWAY (AOP) FOR SKIN SENSITISATION GENERAL INTRODUCTION Activation of dendritic cells key event based test method
Background and principles of the tests included in the key event based test method
LITERATURE
Appendix 1 IN VITRO SKIN SENSITISATION: HUMAN CELL LINE ACTIVATION TEST (H-CLAT)? INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
Preparation of cells
Dose finding assay
Preparation of test chemicals and control substances
Application of test chemicals and control substances
Propidium iodide (PI) staining
Cytotoxicity measurement by flow cytometry and estimation of CV75 value
CD86/CD54 expression measurement Preparation of the test chemicals and control substances
Application of test chemicals and control substances
Cell staining and analysis
DATA AND REPORTING Data evaluation
Prediction model
Acceptance criteria
Test report
LITERATURE
Appendix 1.1 DEFINITIONS Accuracy : The closeness of agreement between test results and accepted reference values. It is a measure of test performance and one aspect of relevance. The term is often used interchangeably with concordance to mean the proportion of correct outcomes of a test (21). AOP (Adverse Outcome Pathway) : sequence of events from the chemical structure of a target chemical or group of similar chemicals through the molecular initiating event to an in vivo outcome of interest (22). Chemical : A substance or a mixture. CV75 : The estimated concentration showing 75 % cell viability. EC150 : the concentrations showing the RFI values of 150 in CD86 expression EC200 : the concentrations showing the RFI values of 200 in CD54 expression Flow cytometry : a cytometric technique in which cells suspended in a fluid flow one at a time through a focus of exciting light, which is scattered in patterns characteristic to the cells and their components; cells are frequently labeled with fluorescent markers so that light is first absorbed and then emitted at altered frequencies. Hazard : Inherent property of an agent or situation having the potential to cause adverse effects when an organism, system or (sub) population is exposed to that agent. IATA (Integrated Approach to Testing and Assessment) : A structured approach used for hazard identification (potential), hazard characterisation (potency) and/or safety assessment (potential/potency and exposure) of a chemical or group of chemicals, which strategically integrates and weights all relevant data to inform regulatory decision regarding potential hazard and/or risk and/or the need for further targeted and therefore minimal testing. Medium control : An untreated replicate containing all components of a test system. This sample is processed with test chemical-treated samples and other control samples to determine whether the solvent/vehicle interacts with the test system. Mixture : A mixture or a solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. Positive control : A replicate containing all components of a test system and treated with a substance known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Pre-haptens : chemicals which become sensitisers through abiotic transformation Pro-haptens : chemicals requiring enzymatic activation to exert skin sensitisation potential Relative fluorescence intensity (RFI) : Relative values of geometric mean fluorescence intensity (MFI) in chemical-treated cells compared to MFI in solvent/vehicle-treated cells. Relevance : Description of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test (21). Reliability : Measures of the extent that a test can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility and intra-laboratory repeatability (21). Run : A run consists of one or more test chemicals tested concurrently with a solvent/vehicle control and with a positive control. Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test. It is a measure of accuracy for a test that produces categorical results, and is an important consideration in assessing the relevance of a test(21). Staining buffer : A phosphate buffered saline containing 0,1 % bovine serum albumin. Solvent/vehicle control : An untreated sample containing all components of a test system except of the test chemical, but including the solvent/vehicle that is used. It is used to establish the baseline response for the samples treated with the test chemical dissolved or stably dispersed in the same solvent/vehicle. When tested with a concurrent medium control, this sample also demonstrates whether the solvent/vehicle interacts with the test system. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test. It is a measure of accuracy for a test that produces categorical results and is an important consideration in assessing the relevance of a test (21). Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Test chemical : Any substance or mixture tested using this method. United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) : A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (23). UVCB : substances of unknown or variable composition, complex reaction products or biological materials. Valid test : A test considered to have sufficient relevance and reliability for a specific purpose and which is based on scientifically sound principles. A test is never valid in an absolute sense, but only in relation to a defined purpose (21). Appendix 1.2 PROFICIENCY SUBSTANCES Prior to routine use of the test described in this Appendix to test method B.71, laboratories should demonstrate technical proficiency by correctly obtaining the expected h-CLAT prediction for the 10 substances recommended in Table 1 and by obtaining CV75, EC150 and EC200 values that fall within the respective reference range for at least 8 out of the 10 proficiency substances. Proficiency substances were selected to represent the range of responses for skin sensitisation hazards. Other selection criteria were that the substances are commercially available, and that high-quality in vivo reference data as well as high quality in vitro data generated with the h-CLAT method are available. Also, published reference data are available for the h-CLAT method (3) (14). Table 1 Recommended substances for demonstrating technical proficiency with the h-CLAT method
Appendix 2 IN VITRO SKIN SENSITISATION: U937 CELL LINE ACTIVATION TEST (U-SENS™) INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
Preparation of cells
Preparation of test chemicals and control substances
Application of test chemicals and control substances
Cell staining
Flow cytometry analysis
DATA AND REPORTING Data evaluation
Prediction model
Acceptance criteria
Test report
LITERATURE
Appendix 2.1 DEFINITIONS Accuracy : The closeness of agreement between test results and accepted reference values. It is a measure of test performance and one aspect of relevance. The term is often used interchangeably with concordance to mean the proportion of correct outcomes of a test (14). AOP (Adverse Outcome Pathway) : sequence of events from the chemical structure of a target chemical or group of similar chemicals through the molecular initiating event to an in vivo outcome of interest (15). CD86 Concentration response : There is concentration-dependency (or concentration response) when a positive concentration (CD86 S.I. ≥ 150) is followed by a concentration with an increasing CD86 S.I. Chemical : A substance or a mixture. CV70 : The estimated concentration showing 70 % cell viability. Drift : A drift is defined by i) the corrected %CD86+ value of the untreated control replicate 3 is less than 50 % of the mean of the corrected %CD86+ value of untreated control replicates 1and 2; and ii) the corrected %CD86+ value of the negative control replicate 3 is less than 50 % of mean of the corrected %CD86+ value of negative control replicates 1 and 2. EC150 : the estimated concentrations showing the 150 % S.I. of CD86 expression. Flow cytometry : a cytometric technique in which cells suspended in a fluid flow one at a time through a focus of exciting light, which is scattered in patterns characteristic to the cells and their components; cells are frequently labeled with fluorescent markers so that light is first absorbed and then emitted at altered frequencies. Hazard : Inherent property of an agent or situation having the potential to cause adverse effects when an organism, system or (sub) population is exposed to that agent. IATA (Integrated Approach to Testing and Assessment) : A structured approach used for hazard identification (potential), hazard characterisation (potency) and/or safety assessment (potential/potency and exposure) of a chemical or group of chemicals, which strategically integrates and weights all relevant data to inform regulatory decision regarding potential hazard and/or risk and/or the need for further targeted and therefore minimal testing. Mixture : A mixture or a solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one main constituent is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. Positive control : A replicate containing all components of a test system and treated with a substance known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Pre-haptens : chemicals which become sensitisers through abiotic transformation, e.g. through oxidation. Pro-haptens : chemicals requiring enzymatic activation to exert skin sensitisation potential. Relevance : Description of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test (14). Reliability : Measures of the extent that a test can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility and intra-laboratory repeatability (14). Run : A run consists of one or more test chemicals tested concurrently with a solvent/vehicle control and with a positive control. Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test. It is a measure of accuracy for a test that produces categorical results, and is an important consideration in assessing the relevance of a test (14). S.I. : Stimulation Index. Relative values of geometric mean fluorescence intensity in chemical-treated cells compared to solvent-treated cells. Solvent/vehicle control : An untreated sample containing all components of a test system except of the test chemical, but including the solvent/vehicle that is used. It is used to establish the baseline response for the samples treated with the test chemical dissolved or stably dispersed in the same solvent/vehicle. When tested with a concurrent medium control, this sample also demonstrates whether the solvent/vehicle interacts with the test system. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test. It is a measure of accuracy for a test that produces categorical results and is an important consideration in assessing the relevance of a test (14). Staining buffer : A phosphate buffered saline containing 5 % foetal calf serum. Substance : A chemical element and its compounds in the natural state or obtained by any production process, inducing any additive necessary to preserve its stability and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing it composition. Test chemical : Any substance or mixture tested using this test. United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN GHS) : A system proposing the classification of chemicals (substances and mixtures) according to standardized types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (16). UVCB : substances of unknown or variable composition, complex reaction products or biological materials. Valid test : A test considered to have sufficient relevance and reliability for a specific purpose and which is based on scientifically sound principles. A test is never valid in an absolute sense, but only in relation to a defined purpose (14). Appendix 2.2 PROFICIENCY SUBSTANCES Prior to routine use of the test described in this Appendix to test method B.71, laboratories should demonstrate technical proficiency by correctly obtaining the expected U-SENS™ prediction for the 10 substances recommended in Table 1 and by obtaining CV70 and EC150 values that fall within the respective reference range for at least 8 out of the 10 proficiency substances. Proficiency substances were selected to represent the range of responses for skin sensitisation hazards. Other selection criteria were that the substances are commercially available, and that high-quality in vivo reference data as well as high quality in vitro data generated with the U-SENS™ test are available. Also, published reference data are available for the U-SENS™ test (1) (8). Table 1 Recommended substances for demonstrating technical proficiency with the U-SENS™ test
Appendix 3 IN VITRO SKIN SENSITISATION: IL-8 LUC ASSAY INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
DEMONSTRATION OF PROFICIENCY
PROCEDURE
Preparation of cells
Preparation of the test chemical and control substances
Luciferase activity measurements
DATA AND REPORTING Data evaluation
Prediction model
Figure 1 Prediction model for final judgment Acceptance criteria
Test report
LITERATURE
Appendix 3.1 DEFINITIONS Accuracy : The closeness of agreement between test results and accepted reference values. It is a measure of test performance and one aspect of relevance. The term is often used interchangeably with concordance to mean the proportion of correct outcomes of a test (16). AOP (Adverse Outcome Pathway) : Sequence of events from the chemical structure of a target chemical or group of similar chemicals through the molecular initiating event to an in vivo outcome of interest (20). Chemical : A substance or a mixture. CV05 : Cell viability 05, i.e. minimum concentration at which chemicals show less than 0,05 of Inh-GAPLA. FInSLO-LA : Abbreviation used in the validation report and in previous publications regarding the IL-8 Luc assay to refer to Ind-IL8LA. See Ind-IL8LA for definition. GAPLA : Luciferase Activity of Stable Luciferase Red (SLR) (max = 630 nm), regulated by GAPDH promoter and demonstrates cell viability and viable cell number. Hazard : Inherent property of an agent or situation having the potential to cause adverse effects when an organism, system or (sub) population is exposed to that agent. IATA (Integrated Approach to Testing and Assessment) : A structured approach used for hazard identification (potential), hazard characterisation (potency) and/or safety assessment (potential/potency and exposure) of a chemical or group of chemicals, which strategically integrates and weights all relevant data to inform regulatory decision regarding potential hazard and/or risk and/or the need for further targeted and therefore minimal testing. II-SLR-LA : Abbreviation used in the validation report and in previous publications regarding the IL-8 Luc assay to refer to Inh-GAPLA. See Inh-GAPLA for definition IL-8 (Interleukin-8) : A cytokine derived from endothelial cells, fibroblasts, keratinocytes, macrophages, and monocytes that causes chemotaxis of neutrophils and T-cell lymphocytes. IL8LA : Luciferase Activity of Stable Luciferase Orange (SLO) (max = 580 nm), regulated by IL-8 promoter. Ind-IL8LA : Fold induction of nIL8LA. It is obtained by dividing the nIL8LA of THP-G8 cells treated with chemicals by that of non-stimulated THP-G8 cells and represents the induction of IL-8 promoter activity by chemicals. Inh-GAPLA : Inhibition of GAPLA. It is obtained by dividing GAPLA of THP-G8 treated with chemicals with GAPLA of non-treated THP-G8 and represents cytotoxicity of chemicals. Minimum induction threshold (MIT) : the lowest concentration at which a chemical satisfies the positive criteria Mixture : A mixture or a solution composed of two or more substances. Mono-constituent substance : A substance, defined by its quantitative composition, in which one main constituent is present to at least 80 % (w/w). Multi-constituent substance : A substance, defined by its quantitative composition, in which more than one of the main constituents is present in a concentration ≥ 10 % (w/w) and < 80 % (w/w). A multi-constituent substance is the result of a manufacturing process. The difference between mixture and multi-constituent substance is that a mixture is obtained by blending of two or more substances without chemical reaction. A multi-constituent substance is the result of a chemical reaction. nIL8LA : The SLO luciferase activity reflecting IL-8 promoter activity (IL8LA) normalised by the SLR luciferase activity reflecting GAPDH promoter activity (GAPLA). It represents IL-8 promoter activity after considering cell viability or cell number. nSLO-LA : Abbreviation used in the validation report and in previous publications regarding the IL-8 Luc assay to refer to nIL8LA. See nIL8LA for definition Positive control : A replicate containing all components of a test system and treated with a substance known to induce a positive response. To ensure that variability in the positive control response across time can be assessed, the magnitude of the positive response should not be excessive. Pre-haptens : Chemicals which become sensitisers through abiotic transformation. Pro-haptens : Chemicals requiring enzymatic activation to exert skin sensitisation potential. Relevance : Description of relationship of the test to the effect of interest and whether it is meaningful and useful for a particular purpose. It is the extent to which the test correctly measures or predicts the biological effect of interest. Relevance incorporates consideration of the accuracy (concordance) of a test (16). Reliability : Measures of the extent that a test can be performed reproducibly within and between laboratories over time, when performed using the same protocol. It is assessed by calculating intra- and inter-laboratory reproducibility and intra-laboratory repeatability (16). Run : A run consists of one or more test chemicals tested concurrently with a solvent/vehicle control and with a positive control. Sensitivity : The proportion of all positive/active chemicals that are correctly classified by the test. It is a measure of accuracy for a test that produces categorical results, and is an important consideration in assessing the relevance of a test (16). SLO-LA : Abbreviation used in the validation report and in previous publications regarding the IL-8 Luc assay to refer to IL8LA. See IL8LA for definition. SLR-LA : Abbreviation used in the validation report and in previous publications regarding the IL-8 Luc assay to refer to GAPLA. See GAPLA for definition. Solvent/vehicle control : An untreated sample containing all components of a test system except of the test chemical, but including the solvent/vehicle that is used. It is used to establish the baseline response for the samples treated with the test chemical dissolved or stably dispersed in the same solvent/vehicle. When tested with a concurrent medium control, this sample also demonstrates whether the solvent/vehicle interacts with the test system. Specificity : The proportion of all negative/inactive chemicals that are correctly classified by the test. It is a measure of accuracy for a test that produces categorical results and is an important consideration in assessing the relevance of a test (16). Substance : A chemical elements and its compounds in the natural state or obtained by any production manufacturing process, including any additive necessary to preserve the its stability of the product and any impurities deriving from the process used, but excluding any solvent which may be separated without affecting the stability of the substance or changing its composition. Surfactant : Also called surface-active agent, this is a substance, such as a detergent, that can reduce the surface tension of a liquid and thus allow it to foam or penetrate solids; it is also known as a wetting agent. (TG437) Test chemical : Any substance or mixture tested using this method. THP-G8 : An IL-8 reporter cell line used in IL-8 Luc assay. The human macrophage-like cell line THP-1 was transfected the SLO and SLR luciferase genes under the control of the IL-8 and GAPDH promoters, respectively. United Nations Globally Harmonized System of Classification and Labeling of Chemicals (UN GHS) : A system proposing the classification of chemicals (substances and mixtures) according to standardised types and levels of physical, health and environmental hazards, and addressing corresponding communication elements, such as pictograms, signal words, hazard statements, precautionary statements and safety data sheets, so that to convey information on their adverse effects with a view to protect people (including employers, workers, transporters, consumers and emergency responders) and the environment (21). UVCB : substances of unknown or variable composition, complex reaction products or biological materials. Valid test method : A test considered to have sufficient relevance and reliability for a specific purpose and which is based on scientifically sound principles. A test is never valid in an absolute sense, but only in relation to a defined purpose. Appendix 3.2 PRINCIPLE OF MEASUREMENT OF LUCIFERASE ACTIVITY AND DETERMINATION OF THE TRANSMISSION COEFFICIENTS OF OPTICAL FILTER FOR SLO AND SLR MultiReporter Assay System -Tripluc- can be used with a microplate-type luminometer with a multi-colour detection system, which can equip an optical filter (e.g. Phelios AB-2350 (ATTO), ARVO (PerkinElmer), Tristar LB941 (Berthold)). The optical filter used in measurement is 600–620 nm long or short pass filter, or 600–700 nm band pass filter. Measurement of two-colour luciferases with an optical filter This is an example using Phelios AB-2350 (ATTO). This luminometer is equipped with a 600 nm long pass filter (R60 HOYA Co., 600 nm LP, Filter 1) for splitting SLO (max = 580 nm) and SLR (max = 630 nm) luminescence. To determine transmission coefficients of the 600 nm LP, first, using purified SLO and SLR luciferase enzymes, measure i) the SLO and SLR bioluminescence intensity without filter (F0), ii) the SLO and SLR bioluminescence intensity that passed through 600 nm LP (Filter 1), and iii) calculate the transmission coefficients of 600 nm LP for SLO and SLR listed below.
When the intensity of SLO and SLR in test sample are defined as O and R, respectively, i) the intensity of light without filter (all optical) F0 and ii) the intensity of light that transmits through 600 nm LP (Filter 1) F1 are described as below. F0=O+R F1=κOR60 x O + κRR60 x R These formulas can be rephrased as follows:
Then using calculated transmittance factors (κOR60 and κRR60) and measured F0 and F1, you can calculate O and R-value as follows:
Materials and methods for determining transmittance factor
Quality control of equipment The procedures described in the IL-8 Luc protocol should be used (18). Appendix 3.3 PROFICIENCY SUBSTANCES Prior to routine use of the test described in this Appendix to test method B.71, laboratories should demonstrate technical proficiency by obtaining the expected IL-8 Luc assay prediction for the 9 substances recommended in Table 1 and by obtaining values that fall within the respective reference range for at least 8 out of the 9 proficiency substances (selected to represent the range of responses for skin sensitisation hazards). Other selection criteria were that the substances are commercially available, and that high-quality in vivo reference data as well as high quality in vitro data generated with the IL-8 Luc assay are available. Also, published reference data are available for the IL-8 Luc assay (6) (1). Table 1 Recommended substances for demonstrating technical proficiency with the IL-8 Luc assay
Appendix 3.4 INDEXES AND JUDGMENT CRITERIA nIL8LA (nSLO-LA) The j-th repetition (j = 1-4) of the i-th concentration (i = 0-11) is measured for IL8LA (SLO-LA) and GAPLA (SLR-LA) respectively. The normalised IL8LA, referred to as nIL8LA (nSLO-LA), and is defined as: nIL8LAij = IL8LAij/GAPLAij This is the basic unit of measurement in this assay. Ind-IL8LA (FInSLO-LA) The fold increase of the averaged nIL8LA (nSLO-LA) for the repetition on the i-th concentration compared with it at the 0 concentration, Ind-IL8LA, is the primary measure of this assay. This ratio is written by the following formula:
The lead laboratory has proposed that a value of 1.4 corresponds to a positive result for the tested chemical. This value is based on the investigation of the historical data of the lead laboratory. Data management team then used this value through all the phases of validation study. The primary outcome, Ind-IL8LA, is the ratio of 2 arithmetic means as shown in equation. 95 % confidence interval (95 % CI) The 95 % confidence interval (95 % CI) based on the ratio can be estimated to show the precision of this primary outcome measure. The lower limit of the 95 % CI ≥ 1 indicates that the nIL8LA with the i-th concentration is significantly greater than that with solvent control. There are several ways to construct the 95 % CI. We used the method known as Fieller’s theorem in this study. This 95 % confidence interval theorem is obtained from the following formula:
Where
t0.975(ν) is 97.5 percentile of the central t distribution with the ν of the degree of freedom, where
Inh-GAPLA (II-SLR-LA) The Inh-GAPLA is a ratio of the averaged GAPLA (SLR-LA) for the repetition of the i-th concentration compared with that with solvent control, and this is written by
Since the GAPLA is the denominator of the nIL8LA, an extremely small value causes large variation in the nIL8LA. Therefore, Ind-IL8LA values with an extremely small value of Inh-GAPLA (less than 0,05) might be considered poor precision. Appendix 3.5 THE SCHEME OF THE METHODS TO DISSOLVE CHEMICALS FOR THE IL-8 LUC ASSAY.
Appendix 3.6 THE SCHEME OF THE METHOD TO DISSOLVE 4-NBB FOR THE POSITIVE CONTROL OF THE IL-8 LUC ASSAY |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
(9) |
In Part C, the following Chapters are added: "C.52 MEDAKA EXTENDED ONE GENERATION REPRODUCTION TEST (MEOGRT) INTRODUCTION
INITIAL CONSIDERATIONS AND LIMITATIONS
PRINCIPLE OF THE TEST
TEST VALIDITY CRITERIA
DESCRIPTION OF THE METHOD Apparatus
Water
Exposure system
Test solutions
Test animals Selection and holding of fish
Acclimation and selection of fish
TEST DESIGN Test concentrations
Replicates within treatment groups and controls
PROCEDURE Initiation of test
Conditions of exposure
Duration of exposure
Feeding regime
Analytical determination and measurements
Observations and measured endpoints
Humane killing of fish
Handling of eggs and larval fish Collection of eggs from breeding pairs to propagate the next generation
Rearing of eggs to hatching
Setup of breeding pairs Fin clipping and determination of genotypic sex
Establishment of breeding pairs
Sampling of sub-adults and endpoint assessment Sampling of non-breeding pair fish
Tissue sampling and vitellogenin measurement
Secondary sex characteristics
Fecundity and fertility assessment
Sampling of adults and endpoint assessment Sampling of breeding pair fish
Histopathology
Other observations
TIMELINE
DATA AND REPORTING Statistical analysis
Data analysis considerations Use of compromised treatment levels
Solvent controls
Test report
LITERATURE
Appendix 1 DEFINITIONS
Appendix 2 SOME CHEMICAL CHARACTERISTICS OF AN ACCEPTABLE DILUTION WATER
Appendix 3 TEST CONDITIONS FOR THE MEOGRT
Appendix 4 GUIDANCE ON TYPICAL CONTROL VALUES It should be noted that these control values are based on a limited number of validation studies, and may be subject to amendment in the light of further experience. Growth Weight and length measurements are taken for all fish sampled at 9 (or 10) and 15 weeks post fertilisation (wpf). Following this protocol will yield expected wet weights at 9 wpf of 85-145 mg for males and 95-150 mg for females. The expected weights at 15 wpf are 250-330 mg for males and 280-350 mg for females. While there may be substantial deviations from these ranges for individual fish, control mean weights substantially outside of these ranges, especially lower, would suggest problems with feeding, temperature control, water quality, disease or any combination of these factors. Hatch Hatching success in controls is typically around 90 %, however, values as low as 80 % are not uncommon. Hatch success less than 75 % may indicate insufficient agitation of the developing eggs or inadequate care in handling the eggs such as lack of timely removal of dead eggs leading to fungal infestation. Survival Survival rates until 3 wpf from hatch and after 3 wpf are usually 90 % or greater for controls but survival rates in early life stages as low as 80 % for controls are not alarming. Survival rates in controls of less than 80 % would be cause for concern and may indicate insufficient cleaning of the aquaria leading to loss of larval fish through disease or from suffocation due to low dissolved oxygen levels. Mortality may also occur as a result of injury during tank cleaning and by the loss of larval fish to the drain system of the tank. Vitellogenin gene While absolute levels of vitellogenin (vtg) gene, expressed as copies/ng of total mRNA, may vary greatly between laboratories due to the procedures or instrumentation used, the ratio of vtg should be around 200 times greater in control females versus control males. It is not uncommon for this ratio to be as high as from 1 000 to 2000, however, ratios less than 200 are suspect and may indicate problems with sample contamination or problems with the procedure and/or reagents used. Secondary sex characteristics For males, the normal range of Secondary Sex Characteristics, defined as the total number of segments in the fin-rays of the anal fin papillae, is 40-80 segments at 9-10 wpf. By 15 wpf, the range for control males should be about 80-120 and 0 for control females. For unexplained reasons, in rare instances some males have no papillae present by 9 wpf but since all control males develop papillae by 15 wpf, this is most likely caused by delayed development. The presence of papillae in control females indicates the presence of XX males in the population. XX-males The normal background incidence of XX males in culture appears to be about 4 % or less at 25 °C with the incidence increasing with increased temperature. Steps should be taken to minimise the proportion of XX males in the population. Since the incidence of XX males appears to have a genetic component and is therefore heritable, monitoring the culture stock and ensuring that XX males are not used to propagate the culture stock is an effective means to reduce the incidence of XX males in the population. Spawning activity Spawning activity in the control replicates should be monitored daily prior to conducting the fecundity assessment. The control pairs can be qualitatively assessed visually for evidence of spawning activity. By12-14 wpf most control pairs should be spawning. Low numbers of spawning pairs by this time indicates potential problems with the health, maturity or well-being of the fish. Fecundity Healthy, well fed 12-14 wpf medaka generally spawn daily, producing in the range of 15 to 50 eggs per day. Egg production for 16 of the recommended 24 control breeding pairs (> 65 %) should produce greater than 20 eggs per pair per day and may reach as high as about 40 eggs per day. Less than this amount may indicate immature, malnourished or unhealthy spawning pairs. Fertility The percentage of fertile eggs for control spawning pairs is typically in the 90 % range with values in the mid-to-upper 90s not uncommon. Fertility rates of less than 80 % for control eggs are suspect and may indicate either unhealthy individuals or less than ideal culture conditions. Appendix 5 AN EXAMPLE OF A FEEDING SCHEDULE An example of a feeding schedule to ensure adequate growth and development to support robust reproduction is shown in Table 1. Deviations from this feeding schedule may be acceptable, but it is recommended that they are tested to verify that acceptable growth and reproduction be observed. In order to follow the suggested feeding schedule, the dry weight of brine shrimp per volume of brine shrimp slurry needs to be determined prior to starting the test. This can be done by weighing a defined volume of brine shrimp slurry that has been dried for 24 hours at 60 °C on pre-weighed pans. To account for the weight of the salts in the slurry, an identical volume of the same salt solution used in the slurry should also be dried, weighed, and subtracted from the dried brine shrimp slurry weight. Alternatively, the brine shrimp can be filtered and rinsed with distilled water before drying, thereby eliminating the need to measure the weight of a “salt blank”. This information is used to convert the information in the Table from dry weight of brine shrimp to volume of brine shrimp slurry to be fed per fish. In addition, it is recommended that aliquots of the brine shrimp slurry are weighed weekly to verify the correct dry weight of brine shrimp being fed. Table 1 Example of a feeding schedule
Appendix 6 EXAMPLES OF AN EGG INCUBATION CHAMBER Example A This incubator consists of a transected glass centrifuge tube, connected by a stainless steel sleeve and held in place by the centrifuge screw top cap. A small glass or stainless steel tube projects through the cap and is positioned near the rounded bottom, gently bubbling air to suspend the eggs and reducing between-egg transmission of saprophytic fungal infections while also facilitating chemical exchange between the incubator and the holding tank. Example B This incubator consists of a glass cylinder body (5 cm diameter and 10 cm height) and stainless wire mesh (0.25 φ and 32 mesh) which is attached to the bottom of the body with a PTFE ring. The incubators are suspended from the lifting bar to tanks, and shaken vertically (approximately 5 cm amplitude) in an appropriate cycle (approximately once every 4 seconds) for medaka eggs. Appendix 7 SCHEMATIC DIAGRAM FOR POOLING AND POPULATING REPLICATES THROUGHOUT THE MEOGRT TEST METHOD Figure 1 Pooling and repopulating replicates throughout the MEOGRT. The figure represents one treatment or 1/2 of a control. Due to pooling, replicate identity is not continuous throughout the test. Note that the term ‘eggs’ refers to viable, fertilised eggs (equivalent to embryos). Treatments and Replication. The test method recommends five test chemical treatments using technical grade material and a negative control. The number of replicates per treatment does not remain constant throughout the MEOGRT, and the number of replicates in the control treatment is double of any single test chemical treatment. In F0, each test chemical treatment has six replicates while the negative control treatment has 12 replicates. Solvents are highly discouraged, and if used, a justification for both the use of a solvent and the choice of solvent should be included in the MEOGRT report. Also, if a solvent is used, two types of controls are necessary: a) a solvent control, and b) a negative control. These two control groups should each consist of a full complement of replicates at all points within the MEOGRT timeline. Throughout test organism development in the F1 generation (and F2, until hatch), this replicate structure remains the same. However, in the adult stage when F1 breeding pairs are setup, the number of reproducing pair replicates per treatment is optimally doubled; therefore there are up to 12 replicate pairs in each test chemical treatment and 24 replicate pairs in the control group (and another 24 replicate pairs in the solvent control, if needed). The determination of hatch from embryos spawned by the F1 pairs is done on the same replicate structure as was done for the embryos spawned by the F0 pairs, meaning initially six replicates per test chemical treatment and 12 replicates in the control group(s). Appendix 8 COUNTING ANAL FIN PAPILLAE Major Materials and Reagents
Procedures After necropsy, the anal fin should be imaged to allow for convenient counting of anal fin papillae. While imaging is the recommended method, the anal fin can be fixed with Davidson’s fixative or other appropriate fixative for approximately 1 minute. It is important to keep the anal fin flat during fixation to allow for easier counting of papillae. The carcass with the anal fin can be stored in Davidson’s fixative or other appropriate fixative until analysed. Count the number of joint plates (see Figure 1) with papillae which protrude from the posterior margin of the joint plate. Figure 1 Anal fin papillae Appendix 9 DETAILED TIMELINE OF MEOGRT Test Weeks 1-3 (F0) The F0 generation spawning fish that have met the selection criteria (see para. 16-20) are exposed for three weeks to allow the developing gametes and gonadal tissues to be exposed to the test chemical. Each replicate tank houses a single breeding fish pair (XX female-XY male breeding pair). Spawned eggs are collected, counted and assessed for fertility for 21 consecutive days, starting at Test Day 1. Test Week 4 (F0 and F1) It is preferable that the fertilised and viable eggs (embryos) are collected on a single day; however, if there are not enough embryos, the embryos may be collected over two days If collected over two days, all embryos within the treatments that were collected on the first day are pooled with those collected on the second day. Then the total pooled embryos for each treatment are randomly distributed to each of the replicate incubators at 20 embryos per incubator. The mortalities of fertilised eggs (embryos) are checked and recorded daily. Dead eggs are removed from the incubators (death in fertilised eggs may be denoted by, particularly in the early stages, a marked loss of translucency and change in colouration, caused by coagulation and/or precipitation of protein, leading to a white opaque appearance; OECD 2010). Note: If a single treatment requires a second day of collection, all treatments (including controls) need to follow this procedure. If after the second day of collection there are inadequate numbers of embryos within a treatment to load 20 embryos per incubator, then reduce the number of embryos loaded within that specific treatment to 15 embryos per incubator. If there are not enough embryos to load 15 per incubator, then reduce the number of replicate incubators until there are enough embryos for 15 per incubator. Additionally, more breeding pairs per treatment and controls could be added in F0 to produce more eggs to reach the recommended 20 per replicate. On Test Day 24, the F0 breeding pairs are humanely killed and weight and length are recorded. If necessary F0 breeding pairs maybe kept for an additional 1-2 days in order to restart F1. Test Weeks 5-6 (F1) One to two days before the anticipated start of hatching, stop or reduce the agitation of the incubating eggs to expedite hatching. As embryos hatch on each day, hatchlings are pooled by treatment and systematically distributed to each replicate larval tank within a specific treatment with no more than 12 hatchlings. This is done by randomly selecting hatchlings and placing a single hatchling in successive replicates in an indiscriminate draw, moving in order through the specific treatment replicates until all replicates within the treatment have 12 hatchlings. If there are not enough hatchlings to fill all replicates then ensure as many replicates as possible have 12 hatchlings to start the F1 phase. The eggs that have not hatched by twice the median control day of hatch are considered non-viable and discarded. The number of hatchlings is recorded and hatching success (hatchability) is calculated in each replicate. Test Weeks 7-11 (F1) The survival of larval fish is checked and recorded daily in all replicates. On Test Day 43, the number of surviving fish in each replicate is recorded as well as the initial number of hatchlings placed in the replicate (nominally twelve). This allows for the calculation of the percent survival from hatch to the subadult stage. Test Week 12 (F1) On Test Day 78-85, a small sample is taken from the caudal fin of each fish to determine the genotypic sex of the individual (i.e., fin clipping) for all fish. This information is used to establish breeding pairs. Within three days after the genotypic sex of each fish is determined, 12 breeding pairs per treatment and 24 pairs per control are randomly established. Two XX and XY fish from each replicate are randomly selected and then pooled by sex, and then randomly selected to establish a breeding pair (i.e., XX-XY pair). A minimum 12 replicates per chemical treatment and minimum 24 replicates for the control are established with one breeding pair per replicate. If a replicate does not have either two XX or two XY fish available for pooling, then fish with the appropriate gender genotype should be obtained from other replicates within the treatment. The remaining fish (maximum 8 fish per replicate) are humanely killed and sampled for the various subadult endpoints. The dmy data (XX or XY) for all the subadult samples are retained to ensure that all endpoint data can be related to the genetic sex of each individual fish. Test Weeks 13-14 (F1) The exposure continues as the subadult breeding pairs develop into adults. On Test Day 98 (i.e. the day before egg collection is started), eggs are removed from both the aquaria and the females. Test Weeks 15-17 (F1) Spawned eggs are collected daily for 21 consecutive days in each replicate, and assessed for fecundity and fertility. Test Week 18 (repeat of Test Week 4) (F1 and F2) On Test Day 120, eggs collection is done in each replicate tank in the morning. The collected eggs are assessed and fertilised eggs (filaments removed) from each of the breeding pairs are pooled by treatment, and systematically distributed to egg incubation chambers with 20 fertilised eggs per incubator. The incubators may be placed in separate “incubator tanks” set up for each treatment or in the replicate tank that upon hatch will contain the hatched larvae. It is preferable that the embryos are collected on a single day; however, if there are not enough embryos, the embryos may be collected over two days. If collected over two days, all embryos within the treatments that were collected on the first day are pooled with those collected on the second day. Then the total pooled embryos for each treatment are randomly distributed to each of the replicate incubators at 20 embryos per incubator. Note: If a single treatment requires a second day of collection, all treatments (including controls) need to follow this procedure. If after the second day of collection there is inadequate numbers of embryos within a treatment to load 20 embryos per incubator, reduce the number of embryos loaded within that specific treatment to 15 embryos per incubator. If there are not enough embryos to load 15 per incubator, reduce the number of replicate incubators until there are enough embryos for 15 per incubator. On Test Day 121 (or Test Day 122, to ensure the F2 has started well), the F1 breeding pairs are humanely killed and analysed for the adult endpoints. If necessary F1 breeding pairs maybe kept for an additional 1-2 days in order to restart F2. Test Weeks 19-20 (F2) One to two days before the anticipated start of hatching, stop or reduce the agitation of the incubating eggs to expedite hatching. If the test is terminated by the completion of the F2 hatching, each day the hatchlings are tallied and discarded. (Embryos that have not hatched after a prolonged incubation time, defined as twice the median control day of hatch, are considered non-viable). Appendix 10 STATISTICAL ANALYSIS The types of biological data generated in the MEOGRT are not unique to it and except for pathology data, many appropriate statistical methodologies have been developed to properly analyse similar data depending on the characteristics of the data including normality, variance homogeneity, whether the study design lends itself to hypothesis testing or regression analysis, parametric versus non-parametric tests, etc. In general principle, the suggested statistical analyses follow the recommendations of the OECD for ecotoxicity data (OECD 2006) and a decision flowchart for MEOGRT data analysis can be seen in Figure 2. It is assumed that most often the datasets will display monotonic responses. Additionally, the issue of using a one-tailed statistical test versus a two-tailed statistical test should be considered. Unless there is a biological reasoning that would make a one-tailed test inappropriate, it is suggested that one-tailed tests be used. While the following section recommends certain statistical tests, if more appropriate and/or powerful statistical methods are developed for application to the specific data generated in the MEOGRT, those statistical tests would be used to leverage those advantages. The MEOGRT data should be analysed separately for each genotypic sex. There are two strategies to analysing the data from sex reversed fish (either XX males or XY females). 1) Censor all data from sex reversed fish across the entire test except the prevalence of sex reversal in each replicate. 2) Leave the data from all sex reversed fish in the dataset and analyse based upon genotype. Histopathology data Histopathology data are reported as severity scores which are evaluated using a newly developed statistical procedure, the Rao-Scott Cochrane-Armitage by Slices (RSCABS), (Green et al., 2014). The Rao-Scott adjustment retains test-replication information; the by Slices procedure incorporates the biological expectation that severity scores tend to increase with increasing treatment concentrations. For each diagnosis, the RSCABS output specifies which treatments have higher prevalence of pathology than controls and the associated severity level. Fecundity data Analyses for fecundity data consist of a step-down Jonckheere-Terpstra or Williams’ test to determine treatment effects, provided the data are consistent with a monotone concentration-response. With a step-down test, all comparisons are done at the 0,05 significance level and no adjustment for the number of comparisons made. The data are expected to be consistent with a monotone concentration response, but this can be verified either by visual inspection of the data or by constructing linear and quadratic contrasts of treatment means after a rank-order transform of the data. Unless the quadratic contrast is significant and the linear contrast is not significant, the trend test is done. Otherwise, Dunnett’s test is used to determine treatment effects if the data are normally distributed with homogeneous variances. If those requirements are not met, then Dunn’s test with a Bonferonni-Holm adjustment is used. All indicated tests are done independently of any overall F- or Kruskal-Wallis test. Further details are provided in OECD 2006. Alternative methods can be used, such as a generalised linear model with Poisson errors for egg counts (with no transform), if justified statistically (Cameron and Trividi, 2013). Statistical advice is recommended if an alternative approach is used. Daily Egg Count within a Single Generation The ANOVA model is given by Y=Time*Time+Treatment + *Treatment + Time*Treatment + *Time*Treatment, with random effects of Replicate(Generation*Treatment), and Time*Replicate(Treatment), allowing for unequal variance components of both types across generations. Here Time refers to the frequency of egg counts (e.g., Day or Week). This is a repeated measures analysis, with the correlations between observations on the same replicates accounting for the repeated measures nature of the data. Main effects of treatment are tested using the Dunnett (or Dunnett-Hsu) test, which adjusts for the number of comparisons. Adjustments for the main effect of generation or time are needed, for with these two factors, there is no “control” level and every pair of levels is a comparison of possible interest. For these two main effects, if the F-test for the main effect is significant at the 0,05 level, then the pairwise comparisons across levels of that factor can then be tested at the 0,05 level without further adjustment. The model includes two- and three-factor interactions, so that a main effect for, say, time, may not be significant even though time has a significant impact on results. Thus, if a two- or three-factor interaction involving time is significant at the 0,05 level, then one can accept the comparisons of levels of time at the 0,05 significance level without further adjustment. Next are F-tests for significance of treatment within time, the so-called slices in the ANOVA table. If, for example, the slice for treatment within F1 and time 12, is significant at the 0,05 level, then the pairwise comparisons for treatment within F1 and time 12 can be accepted at the 0,05 level without further adjustment. Similar statements apply to tests for time within F1 and treatment and for generation within a time and treatment. Finally, for comparisons not falling under any of the above categories, comparisons should be adjusted using the Bonferroni-Holm adjustment to p-values. Further information on analyses of such models can be found in Hocking (1985) and Hochberg and Tamhane (1987). Alternatively, the raw data are recorded and presented in the study report as the fecundity (number of eggs) per replicate for each day. The replicate mean of the raw data should be calculated then a square root transformation applied. A one-way ANOVA on the transformed replicate means should be calculated followed by Dunnett contrasts. It may also be helpful to visually inspect the fecundity data of each treatment and/or replicate with a scatterplot that displays the data through time. This will allow an informal assessment of potential effects through time. All other biological data The statistical analyses are based on the underlying assumption that with proper dose selection the data will be monotonic. Thus, data are assumed to be monotonic and they are formally evaluated for monotonicity by using linear and quadratic contrasts. If the data are monotonic, a Jonckheere-Terpstra on replicate medians trend test (as advised in OECD 2006) is recommended. If the quadratic contrast is significant and the linear contrast is not, the data are considered non-monotonic. If the data are non-monotonic, in particular because of the reduced response of the highest one or two treatments, consideration should be given to censoring the dataset so that the analysis is done without those treatments. This decision will need to be made with professional judgment and all available data, especially data that indicates overt toxicity at those treatment levels. For weight and length, no transforms are recommended although they may occasionally be necessary. However, a log transformation is recommended for the vitellogenin data; a square root transformation is recommended for the SSC data (anal fin papillae); an arcsine-square root transformation is recommended for the data on proportion hatching, percent survival, sex ratio, and percent fertile eggs. Time to hatch and time to first spawn should be treated as time to event data, with individual embryos not hatching in the defined period or replicates never spawning treated as right-censored data. Time to hatch should be calculated from the median day of hatch of each replicate. These endpoints should be analysed using a mixed-effects Cox proportional hazard model. The biological data from adult samples has one measurement per replicate, that is, there are one XX fish and one XY fish per replicate aquarium. Therefore, it is recommended that a one-way ANOVA be done on the replicate means. If the assumptions of the ANOVA (normality and variance homogeneity as assessed on the residuals of the ANOVA by Shapiro-Wilks test and Levene’s test, respectively) are met, Dunnett contrasts should be used to determine treatments that were different from the control. On the other hand, if the assumptions of the ANOVA are not met, then a Dunn’s test should be done to determine which treatments were different from control. A similar procedure is recommended for data that are in the form of percentages (fertility, hatch, and survival). The biological data from subadult samples has from 1 to 8 measurements per replicate, that is, there can be variable numbers of individuals that contribute to the replicate mean for each genotypic sex. Therefore, it is recommended that a mixed effects ANOVA model be used followed by Dunnett contrasts, if the normality and variance homogeneity assumptions were met (on the residuals of the mixed effects ANOVA). If they were not met, then a Dunn’s test should be done to determine which treatments were different from control. Figure 2 Flow chart for the recommended statistical procedures for MEOGRT data analysis LITERATURE
C.53 THE LARVAL AMPHIBIAN GROWTH AND DEVELOPMENT ASSAY (LAGDA) INTRODUCTION
INITIAL CONSIDERATIONS AND LIMITATIONS
SCIENTIFIC BASIS FOR THE TEST METHOD
PRINCIPLE OF THE TEST
TEST VALIDITY CRITERIA
DESCRIPTION OF THE METHODS Apparatus
Water Source and quality
Iodide concentration in test water
Exposure system
Chemical delivery: preparation of test solutions
Test animals Test species
Adult care and breeding
TEST DESIGN Test concentrations
Replicates within treatment groups and controls
PROCEDURE Assay overview
Exposure conditions
Duration of exposure to the test chemical
Initiation of assay
Feeding regime
Analytical chemistry
Observations and endpoint measurements
Mortality and daily observations
Larval sub-sampling Outline of larval sub-sampling:
Humane killing of tadpoles
Morphometrics (weight and length)
Tissue Collection and Fixation
Thyroid histology
Figure 2: Landmarks for measuring snout-vent length for the LAGDA in NF Stage 62 (a) and juvenile frogs (b). The defining characteristics of NF stage 62 (a): the head is the same width as the trunk, the olfactory nerve length is shorter than the diameter of the olfactory bulb (dorsal view), and the forelimbs are at the level of the heart (ventral view). Images adapted from Nieuwkoop and Faber (1994). End of larval exposure
Cull after NF stage 66
Juvenile Sampling Outline of juvenile sampling
Humane killing of frogs
Morphometrics (weight and length)
Plasma VTG (option)
Genetic sex determination
Tissue collection and fixation for histopathology
Histopathology
DATA AND REPORTING Statistical analysis
Data analysis considerations Use of compromised replicates and treatments
Solvent control
Test report
LITERATURE
Appendix 1 DEFINITIONS Apical endpoint : Causing effect at population level. Chemical : A substance or a mixture ELISA : Enzyme-Linked Immunosorbent Assay ECx : (Effect concentration for x % effect) is the concentration that causes an x % of an effect on test organisms within a given exposure period when compared with a control. For example, an EC50 is a concentration estimated to cause an effect on a test end point in 50 % of an exposed population over a defined exposure period. dpf : Days post fertilization Flow-through test : A test with continued flow of test solutions through the test system during the duration of exposure. HPG axis : hypothalamic-pituitary-gonadal axis IUPAC : International Union of Pure and Applied Chemistry. Lowest observed effect concentration (LOEC) : is the lowest tested concentration of a test chemical at which the chemical is observed to have a statistically significant effect (at p < 0.05) when compared with the control. However, all test concentrations above the LOEC should have a harmful effect equal to or greater than those observed at the LOEC. When these two conditions cannot be satisfied, a full explanation should be given for how the LOEC (and hence the NOEC) has been selected. Appendix 7 provides guidance. Median Lethal Concentration (LC50) : is the concentration of a test chemical that is estimated to be lethal to 50 % of the test organisms within the test duration. No observed effect concentration (NOEC) : is the test concentration immediately below the LOEC, which when compared with the control, has no statistically significant effect (p < 0.05), within a stated exposure period. SMILES : Simplified Molecular Input Line Entry Specification. Test chemical : Any substance or mixture tested using this Test Method. UVCB : Substances of unknown or variable composition, complex reaction products or biological materials. VTG : Vitellogenin is a phospholipoglycoprotein precursor to egg yolk protein that normally occurs in sexually active females of all oviparous species. Appendix 2 SOME CHEMICAL CHARACTERISTICS OF AN ACCEPTABLE DILUTION WATER
Appendix 3 TEST CONDITIONS FOR THE LAGDA
Appendix 4 FEEDING REGIME It should be noted that although this feeding regime is recommended, alternatives are permissible providing the test organisms grow and develop at an appropriate rate. Larval feeding Preparation for larval diet
Feeding Protocol Table 1 provides a reference regarding the type and amount of feed used during the larval stages of the exposure. The animals should be fed three times per day Monday through Friday and once per day on the weekends. Table 1 Feeding regime for X. laevis larvae in flow-through conditions
Larval to juvenile diet transition As larvae complete metamorphosis, they transition to a juvenile diet formulation explained below. While this transition is taking place, the larval diet should be reduced as the juvenile feed increases. This can be accomplished by proportionally decreasing the larval feed while proportionally increasing the juvenile feed as each group of five tadpoles surpass NF stage 62 and approach completion of metamorphosis at NF stage 66. Juvenile feeding Juvenile diet Once metamorphosis is complete (stage 66), the feeding regime changes to 3/32 inch premium sinking frog food alone (Xenopus ExpressTM, FL, USA), or equivalent. Preparation of crushed pellet for larval to juvenile transition Sinking frog food pellets are briefly run in a coffee grinder, blender or mortar and pestle in order to reduce the size of the pellets by approximately 1/3. Processing too long results in powder and is discouraged. Feeding protocol Table 2 provides a reference regarding the type and amount of feed used during juvenile and adult life stages. The animals should be fed once per day. It should be noted that as animals metamorphose, they continue receiving a portion of the brine shrimp until > 95 % of animals complete metamorphosis. The animals should not be fed on the day of test termination so feed does not confound weight measurements. Table 2 Feeding regime for X. laevis juveniles in flow-through conditions. It should be noted that unmetamorphosed animals, including those whose metamorphosis has been delayed by the chemical treatment, cannot eat uncrushed pellets
Appendix 5 GENETIC SEX DETERMINATION (GENETIC SEXING) The method of genetic sexing for Xenopus laevis is based on Yoshimoto et al., 2008. Procedures in detail on the genotyping can be obtained from this publication, if needed. Alternative methods (e.g. high-throughput qPCR) may be used if considered suitable. X. laevis primers DM-W marker
Positive Control
DNA purification Purify DNA from muscle or skin tissue using e.g., Qiagen DNeasy Blood and Tissue Kit (cat # 69 506) or similar product according to kit instructions. DNA can be eluted from the spin columns using less buffer to yield more concentrated samples if deemed necessary for PCR. Note that DNA is quite stable, so care should be taken to avoid cross-contamination that could lead to mischaracterisation of males as females, or vice versa. PCR A sample protocol using JumpStartTM Taq from Sigma is outlined in Table 1. Table 1 Sample protocol using JumpStartTM Taq from Sigma
Agarose Gel Electrophoresis (3 %)(sample protocol) 50X TAE
Add water to 100 ml 1X TAE
3:1 Agarose
Method
An agarose gel image showing the band patterns indicative of male and female individuals is shown in Figure 1. Figure 1: Agarose gel image showing the band pattern indicative of a male (♂) individual (single band ~203 bp: DMRT1) and of a female (♀) individual (two bands at ~259 bp: DM-W and 203 bp:DMRT1). LITERATURE Yoshimoto S, Okada E, Umemoto H, Tamura K, Uno Y, Nishida-Umehara C, Matsuda Y, Takamatsu N, Shiba T, Ito M. 2008. A W-linked DM-domain gene, DM-W, participates in primary ovary development in Xenopus laevis. Proceedings of the National Academy of Sciences of the United States of America 105: 2 469-2 474. Appendix 6 MEASUREMENT OF VITELLOGENIN The measurement of vitellogenin (VTG) is made using an enzyme-linked immunosorbent assay (ELISA) method which was originally developed for fathead minnow VTG (Parks et al., 1999). Currently there are no commercially available antibodies for X. laevis. However, given the wealth of information for this protein and the availability of cost-effective commercial antibody production services, it is reasonable that laboratories can easily develop an ELISA to make this measurement (Olmstead et al., 2009). Also Olmstead et al. (2009) provide a description of the assay as modified for VTG in X. tropicalis, as shown below. The method uses an antibody made against X. tropicalis VTG, but it is known also to work for X. laevis VTG. It should be noted that non-competitive ELISAs can also be used, and that these may have lower detection limits than the method described below. Materials and Reagents
Recipes
Sample collection Blood is collected with a heparinised microhematocrit tube and placed on ice. After centrifugation for 3 minutes, the tube is scored, broken open, and the plasma expelled into 0,6 ml microcentrifuge tubes which contain 0,13 units of lyophilised aprotinin. (These tubes are prepared in advance by adding the appropriate amount of aprotinin, freezing, and lyophilising in a speed-vac at low heat until dry.) Store plasma at -80 oC until analysed. Procedure for one plate Coating the plate Mix 20 μl of purified VTG with 22 ml of carbonate buffer (final 3 μg/ml). Add 200 μl to each well of a 96-well plate. Cover the plate with adhesive sealing film and allow to incubate at 37 oC for 2 hours (or 4 oC overnight). Blocking the plate Blocking solution is prepared by adding 2 ml of Normal Goat Serum (NGS) to 38 ml of carbonate buffer. Remove coating solution and shake dry. Add 350 μl of the blocking solution to each well. Cover with adhesive sealing film and incubate at 37 oC for 2 hours (or at 4 oC overnight). Preparation of standards 5.8 μl of purified VTG standard is mixed with 1,5 ml of assay buffer in a 12 x 75 mm borosilicate disposable glass test tube. This yields 12 760 ng/ml. Then a serial dilution is performed by adding 750 μl of the previous dilution to 750 μl of assay buffer to yield final concentrations of 12 760, 6 380, 3 190, 1 595, 798, 399, 199, 100, and 50 ng/ml. Preparation of Samples Start with a 1:300 (e.g., combine 1 μl plasma with 299 μl of assay buffer) or 1:30 dilution of plasma into assay buffer. If a large amount of VTG is expected, additional or greater dilutions may be needed. Try to keep B/Bo within the range of standards. For samples without appreciable VTG, e.g., control males and females (which are all immature), use the 1:30 dilution. Samples diluted less than this may show unwanted matrix effects. Additionally, it is recommended to run a positive control sample on each plate. This comes from a pool of plasma containing high induced levels of VTG. The pool is initially diluted in NGS, divided in aliquots and stored at -80 C. For each plate, an aliquot is thawed, diluted further in assay buffer and run similar to a test sample. Incubation with 1st antibody The 1st Ab is prepared by making a 1:2000 dilution of preadsorbed 1st Ab serum in assay buffer (e.g., 8 μl to 16 ml of assay buffer). Combine 300 μl of 1st Ab solution with 300 μl of sample/standard in a glass tube. The Bo tube is prepared similarly with 300 μl of assay buffer and 300 μl of antibody. Also, a NSB tube should be prepared using 600 μl of assay buffer only, i.e., no Ab. Cover the tubes with Parafilm and vortex gently to mix. Incubate in a 37 oC water bath for 1 hour. Washing the plate Just before the 1st Ab incubation is complete, wash the plate. This is done by shaking out the contents and patting dry on absorbent paper. Then fill wells with 350 μl of wash solution, dump out, and pat dry. A multi-channel repeater pipette or plate washer is useful here. The wash step is repeated two more times for a total of three washes. Loading the plate After the plate has been washed, remove the tubes from the water bath and vortex lightly. Add 200 μl from each sample, standard, Bo, and NSB tube to duplicate wells of the plate. Cover plate with adhesive sealing film and allow to incubate for 1 hour at 37 oC. Incubation with the 2nd antibody At the end of the incubation from the previous step, the plate should be washed three times again, like above. The diluted 2nd Ab is prepared by mixing 2,5 μl of 2nd Ab with 50 ml of assay buffer. Add 200 μl of diluted 2nd Ab to each well, seal like above, and incubate for 1 hour at 37 oC. Addition of substrate After the incubation with the 2nd Ab is complete, wash the plate three times as described earlier. Then add 100 μl of TMB substrate to each well. Allow the reaction to proceed for 10 minutes, preferably out of bright light. Stop the reaction by adding 100 μl of 1 M phosphoric acid. This will change the colour from blue to an intense yellow. Measure the absorbance at 450 nm using a plate reader. Calculate B/Bo Subtract the average NSB value from all measurements. The B/Bo for each sample and standard is calculated by dividing the absorbance value (B) by the average absorbance of the Bo sample. Obtain the standard curve and determine unknown amounts Generate a standard curve with the aid of some computer graphing software (e.g., SlidewriteTM or Sigma Plot®) that will extrapolate quantity from B/Bo of sample based on B/Bo of standards. Typically, the amount is plotted on a log scale and the curve has a sigmoid shape. However, it may appear linear when using a narrow range of standards. Correct sample amounts for dilution factor and report as mg VTG/ml of plasma. Determination of minimum detection limits (MDL) Often, particularly in normal males, it will not be clear how to report results from low values. In these cases, the 95 % "Confidence limits" should be used to determine if the value should be reported as zero or as some other number. If the sample result is within the confidence interval of the zero standard (Bo), the result should be reported as zero. The minimum detection level will be the lowest standard which is consistently different from the zero standard; that is, the two confidence intervals don't overlap. For any sample result which is within the confidence limit of the minimum detection level, or above, the calculated value will be reported. If a sample falls between the zero standard and the minimum detection level confidence intervals, one half of the minimum detection level should be reported for the value of that sample. LITERATURE Olmstead AW, Korte JJ, Woodis KK, Bennett BA, Ostazeski S, Degitz SJ. 2009. Reproductive maturation of the tropical clawed frog: Xenopus tropicalis. General and Comparative Endocrinology 160: 117-123. Parks LG, Cheek AO, Denslow ND, Heppell SA, McLachlan JA, LeBlanc GA, Sullivan CV. 1999. Fathead minnow (Pimephales promelas) vitellogenin: purification, characterisation and quantitative immunoassay for the detection of estrogenic compounds. Comparative Biochemistry and Physiology Part C: Toxicology & Pharmacology 123: 113-125. Appendix 7 STATISTICAL ANALYSIS The LAGDA generates three forms of data to be statistically analysed: (1) Quantitative continuous data, (2) Time-to-event data for developmental rates (Time to NF stage 62) and (3) Ordinal data in the form of severity scores or developmental stages from histopathology evaluations. The recommended statistical analysis decision tree for the LAGDA is shown in Figure 1. Also, some annotations which might be needed to conduct statistical analysis for the measurements from the LAGDA are indicated below. For the analysis decision tree, the results of measurements for mortality, growth (weight and length) and liver-somatic-index (LSI) should be analysed according to the “Other endpoints” branch. Continuous data Data for continuous endpoints should first be checked for monotonicity by rank transforming the data, fitting to an ANOVA model and comparing linear and quadratic contrasts. If the data are monotonic, a step-down Jonckheere-Terpstra trend test should be performed on replicate medians and no subsequent analyses should be applied. An alternative for data that are normally distributed with homogeneous variances is the step-down Williams’ test. If the data are non-monotonic (quadratic contrast is significant and linear is not significant), they should be analysed using a mixed effects ANOVA model. The data should then be assessed for normality (preferably using the Shapiro-Wilk or Anderson-Darling test) and variance homogeneity (preferably using Levene’s test). Both tests are performed on the residuals from the mixed effects ANOVA model. Expert judgment can be used in lieu of these formal tests for normality and variance homogeneity, though formal tests are preferred. If the data are normally distributed with homogeneous variance, then the assumptions of a mixed effect ANOVA are met and a significant treatment effect is determined from Dunnett’s test. Where non-normality or variance heterogeneity is found, then the assumptions of Dunnett’s test are violated and a normalising, variance stabilising transform is sought. If no such transform is found, then a significant treatment effect is determined with a Dunn’s test. Whenever possible, a one-tailed test should be performed as opposed to a two-tailed test, but it requires expert judgment to determine which is appropriate for a given endpoint. Mortality Mortality data should be analysed for the time period encompassing the full test and should be expressed as proportion that died in any particular tank. Tadpoles that do not complete metamorphosis in the given time frame, those tadpoles that are in the larval sub-sample cohort, those juvenile frogs that are culled, and any animal that dies due to experimenter error should be treated as censored data and not included in the denominator of the percent calculation. Prior to any statistical analyses, mortality proportions should be arcsin-square root transformed. An alternative is to use the step-down Cochran-Armitage test, possibly with a Rao-Scott adjustment in the presence of overdispersion. Weight and length (growth data) Males and females are not sexually-dimorphic during metamorphosis so larval sub-sampling growth data should be analysed independent of gender. However, juvenile growth data should be analysed separately based on genetic sex. A log-transformation may be needed for these endpoints since log-normality of size data is not uncommon. Liver-somatic-index (LSI) Liver weights should be normalised as proportions of whole body weights (i.e., LSI) and analysed separately based on genetic sex. Time to NF stage 62 Time to metamorphosis data should be treated as time-to-event data, with any mortalities or individuals not reaching NF stage 62 in 70 days treated as right-censored data (i.e. the true value is greater than 70 days but the study ends before the animals had reached NF stage 62 in 70 days). Median time to NF stage 62 completion of metamorphosis in dilution water controls should be used to determine the test termination date. Median time to completion of metamorphosis could be determined by Kaplan-Meier product-limit estimators. This endpoint should be analysed using a mixed-effects Cox proportional hazard model that takes account of the replicate structure of the study. Histopathology data (severity scores and developmental stages) Histopathology data are in the form of severity scores or developmental stages. A test termed RSCABS (Rao-Scott Cochran-Armitage by Slices) uses a step-down Rao-Scott adjusted Cochran-Armitage trend test on each level of severity in a histopathology response (Green et al., 2014). The Rao-Scott adjustment incorporates the replicate vessel experimental design into the test. The “by Slices” procedure incorporates the biological expectation that severity of effect tends to increase with increasing doses or concentrations, while retaining the individual subject scores and revealing the severity of any effect found. The RSCABS procedure not only determines which treatments are statistically different from controls (i.e., have more severe pathology than controls), but it also determines at which severity score the difference occurs thereby providing much needed context to the analysis. In the case of developmental staging of gonads and reproductive ducts, an additional manipulation should be applied to the data since an assumption of RSCABS is that severity of effect increases with dose. The effect observed could be a delay or acceleration of development. Therefore, developmental staging data should be analysed as reported to detect acceleration in development and then manually inverted prior to a second analysis to detect a delay in development. Figure 1 Statistical analysis decision tree for LAGDA data LITERATURE Green JW, Springer TA, Saulnier AN, Swintek J. 2014. Statistical analysis of histopathology endpoints. Environmental Toxicology and Chemistry 33, 1 108-1 116. Appendix 8 CONSIDERATIONS FOR TRACKING AND MINIMISING THE OCCURRENCE OF SCOLIOSIS Idiopathic scoliosis, usually manifesting as “bent tail” in Xenopus laevis tadpoles, may complicate morphological and behavioural observations in test populations. Efforts should be made to minimise or eliminate the incidence of scoliosis, both in stock and under test conditions. In the definitive test, it is recommended that the prevalence of moderate and severe scoliosis be less than 10 %, to improve confidence that the test can detect treatment-related developmental effects in otherwise healthy amphibian larvae. Daily observations during the definitive test should record both the incidence (individual count) and severity of scoliosis, when present. The nature of the abnormality should be described with respect to location (e.g., anterior or posterior to the vent) and direction of curvature (e.g., lateral or dorsal-to-ventral). Severity may be graded as follows:
A US EPA FIFRA Scientific Advisory Panel (FIFRA SAP 2013) reviewed summary data for scoliosis in fifteen Amphibian Metamorphosis Assays with X. laevis (NF stage 51 through 60+) and provided general recommendations for reducing the prevalence of this abnormality in test populations. The recommendations are relevant to the LAGDA even though this test encompasses a longer developmental timeline. Historical Spawning Performance Generally, high quality, healthy adults should be used as breeding pairs; eliminating breeding pairs that produce offspring with scoliosis may minimise its occurrence over time. Specifically, minimising the use of wild-caught breeding stock may be beneficial. The LAGDA exposure period begins with NF stage 8-to-10 embryos, and it is not feasible to determine at the test outset whether given individuals will exhibit scoliosis. Thus, in addition to tracking the incidence of scoliosis in animals that are placed on test, historical clutch performance (including the prevalence of scoliosis in any larvae allowed to develop) should be documented. It may be useful to further monitor the portion of each clutch not used in a given study and to report these observations (FIFRA SAP 2013). Water Quality It is important to ensure adequate water quality, both in laboratory stock and during the test. In addition to water quality criteria routinely evaluated for aquatic toxicity tests, it may be useful to monitor for and to correct any nutrient deficiencies (e.g., deficiency of vitamin C, calcium, phosphorus) or excess levels of selenium and copper, which are reported to cause scoliosis to varying degrees in laboratory-reared Rana sp. and Xenopus sp. (Marshall et al. 1980; Leibovitz et al. 1992; Martinez et al. 1992; as reported in FIFRA SAP 2013). The use of an appropriate dietary regimen (see Appendix 4), and regular tank cleaning, will generally improve water quality and health of the test specimens. Diet Specific recommendations for a dietary regimen, found to be successful in the LAGDA, are detailed in Appendix 4. It is recommended that feed sources be screened for biological toxins, herbicides, and other pesticides which are known to cause scoliosis in X. laevis or other aquatic animals (Schlenk and Jenkins 2013). For example, exposure to certain cholinesterase inhibitors has been associated with scoliosis in fish (Schultz et al. 1985) and frogs (Bacchetta et al. 2008). LITERATURE Bacchetta, R., P. Mantecca, M. Andrioletti, C. Vismara, and G. Vailati. 2008. Axial-skeletal defects caused by carbaryl in Xenopus laevis embryos. Science of the Total Environment 392: 110 – 118. Schultz, T.W., J.N. Dumont, and R.G. Epler. 1985. The embryotoxic and osteolathyrogenic effects of semicarbazide. Toxicology 36: 185-198. Leibovitz, H.E., D.D. Culley, and J.P. Geaghan. 1982. Effects of vitamin C and sodium benzoate on survival, growth and skeletal deformities of intensively culture bullfrog larvae (Rana catesbeiana) reared at two pH levels. Journal of the World Aquaculture Society 13: 322-328. Marshall, G.A., R.L. Amborski, and D.D. Culley. 1980. Calcium and pH requirements in the culture of bullfrog (Rana catesbeiana) larvae. Journal of the World Aquaculture Society 11: 445-453. Martinez, I., R. Alvarez, I. Herraez, and P. Herraez. 1992. Skeletal malformations in hatchery reared Rana perezi tadpoles. Anatomical Records 233(2): 314-320. Schlenk, D., and Jenkins, F. 2013. Endocrine Disruptor Screening Prog (EDSP) Tier 1 Screening Assays and Battery Performance. US EPA FIFRA SAP Minutes No. 2013-03. May 21-23, 2013. Washington, DC. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Poznámky
(2) Commission Regulation (EC) No 440/2008 of 30 May 2008 laying down test methods pursuant to Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) (OJ L 142, 31.5.2008, p. 1).
(1) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(2) The proficiency substances, sorted first by corrosives versus non-corrosives, then by corrosive subcategory and then by chemical class, were selected from the substances used in the ECVAM validation study of the rat skin TER test method (8) (9). Unless otherwise indicated, the substances were tested at the purity level obtained when purchased from a commercial source (8). The selection included, to the extent possible, substances that: (i) are representative of the range of corrosivity responses (e.g. non-corrosives; weak to strong corrosives) that the VRM is capable of measuring or predicting; (ii) are representative of the chemical classes used in the validation study; (iii) reflect the performance characteristics of the VRM; (iv) have chemical structures that are well-defined; (v) induce definitive results in the in vivo reference test method; (vi) are commercially available; and (vii) are not associated with prohibitive disposal costs.
(3) Chemical class assigned by Barratt et al. (8).
(4) The corresponding UN Packing groups are I, II and III, respectively, for the UN GHS/CLP categories 1A, 1B and 1C.
(5) The pH values were obtained from Fentem et al. (9) and Barratt et al. (8).
(6) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(7) The abbreviation RhE (=Reconstructed human Epidermis) is used for all models based on RhE technology. The abbreviation RHE as used in conjunction with the SkinEthic™ model means the same, but, as part of the name of this specific test method as marketed, is spelled all in capitals.
(8) The proficiency substances, sorted first by corrosives versus non-corrosives, then by corrosive sub-category and then by chemical class, were selected from the substances used in the ECVAM validation studies of EpiSkin™ and EpiDerm™ (8) (9) (10) and from post-validation studies based on data provided by EpiSkin™ (22), EpiDerm™, SkinEthic™ and epiCS® developers (23). Unless otherwise indicated, the substances were tested at the purity level obtained when purchased from a commercial source (8) (10). The selection includes, to the extent possible, substances that: (i) are representative of the range of corrosivity responses (e.g. noncorrosives; weak to strong corrosives) that the VRMs are capable of measuring or predicting; (ii) are representative of the chemical classes used in the validation studies; (iii) have chemical structures that are well-defined; (iv) induce reproducible results in the VRM; (v) induce definitive results in the in vivo reference test method; (vi) are commercially available; and (vii) are not associated with prohibitive disposal costs.
(9) Chemical class assigned by Barratt et al. (8).
(10) The corresponding UN Packing groups are I, II and III, respectively, for the UN GHS/CLP 1A, 1B and 1C.
(11) The VRM in vitro predictions reported in this table were obtained with the EpiSkin™ and the EpiDerm™ test models (VRMs) during post-validation testing performed by the test method developers.
(12) The viability values obtained in the ECVAM Skin Corrosion Validation Studies were not corrected for direct MTT reduction (killed controls were not performed in the validation studies). However, the post-validation data generated by the test method developers that are presented in this table were acquired with adapted controls (23).
(*1) According to the data generated in view of assessing the usefulness of the RhE test models for supporting subcategorisation, it was shown that around 22 % of the sub-category 1A results of the EpiSkin™ test model may actually constitute sub-category 1B or sub-category 1C substances/mixtures (i.e. overclassifications) (see Appendix 3).
(*2) one chemical was tested once in epiCS® because of no availability (23)
(13) LLOQ: Lower Limit of Quantification, defined to cover 1-2 % tissue viability, i.e., 0,8 μg/ml.
(14) ULOQ: Upper Limit of Quantification, defined to be at least two times higher than the highest expected MTT formazan concentration in isopropanol extracts from negative controls i.e., 200 μg/ml.
(15) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(16) The Proficiency Substances are a subset of the substances used in the validation study and the selection is based on the following criteria; (i), the chemicals substances are commercially available; (ii), they are representative of the full range of Draize irritancy scores (from non-irritant to strong irritant); (iii), they have a well-defined chemical structure; (iv), they are representative of the chemical functionality used in the validation process; (v) they provided reproducible in vitro results across multiple testing and multiple laboratories; (vi) they were correctly predicted in vitro, and (vii) they are not associated with an extremely toxic profile (e.g. carcinogenic or toxic to the reproductive system) and they are not associated with prohibitive disposal costs.
(17) In vivo score in accordance with TM B.4 (4).
(18) Under this test method, the UN GHS optional Category 3 (mild irritants) (1) is considered as No Category.
(*3) The original ECVAM Performance Standards (PS) (21) were developed in 2007 upon completion of the prospective validation study (16) which had assessed the performance of test models Nr 1 and 2 in reference to the classification system as described in the 28th amendment to the EU Dangerous Substances Directive (41). In 2008 the UN GHS (1) and EU CLP were introduced, effectively shifting the cut-off value for distinguishing non-classified from classified substances from an in vivo score of 2.0 to 2.3. To adapt to this changed regulatory requirement, the accuracy values and reference chemical list of the ECVAM PS were updated in 2009 (2) (39) (40). As the original PS, also the updated PS were largely based on data from models Nr. 1 and 2 (16), but additionally used data on reference chemicals from model Nr. 3. In 2010, the updated ECVAM PS were used for stipulating the PS related to this TG (8). For the purpose of this test method, EpiSkin™ is considered the VRM, due to the fact that it was used to develop all the criteria of the PS. Detailed information on the validation studies, a compilation of the data generated as well as background to the necessary adaptations of the PS as a consequence of the UN GHS/CLP implementation can be found in the ECVAM/BfR explanatory background document to the corresponding OECD TG 439 (23).
(19) LLOQ: Lower Limit of Quantification, defined to cover 1-2 % tissue viability, i.e. 0,8 μg/ml.
(20) ULOQ: Upper Limit of Quantification, defined to be at least two times higher than the highest expected MTT formazan concentration in isopropanol extracts from negative controls i.e. 200 μg/ml.
(21) last day of the mating period
(22) For a number of measurements in serum and plasma, most notably for glucose, overnight fasting would be preferable. The major reason for this preference is that the increased variability which would inevitably result from non-fasting, would tend to mask more subtle effects and make interpretation difficult. On the other hand, however, overnight fasting may interfere with the general metabolism of the (pregnant) animals, disturbs lactation and nursing behaviour, and, particularly in feeding studies, may disturb the daily exposure to the test chemical. If overnight fasting is adopted, clinical biochemical determinations should be performed after the conduct of functional observations in week 4 of the study for the males. The dams should be retained for an additional day after the pups are removed on e.g. PND 13). Dams should be fasted overnight from lactation day 13-14 and terminal blood used for clinical chemistry parameters.
(23) last day of the mating period
(24) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(25) “Acid derivative” is a non-specific class designation and is broadly defined as a chemical produced from an acid either directly or by modification or partial substitution. This class includes anhydrides, halo acids, salts, and other types of chemicals.
(26) For the EU, the CLP Regulation applies the three skin corrosion subcategories 1A, 1B and 1C.
(27) The twelve substances listed above contain three substances from each of the three UN GHS subcategories for corrosive substances and three non-corrosive substances, are readily available from commercial suppliers, and the UN GHS subcategory is based on the results of high-quality in vivo testing. These substances are taken from the list of 40 reference substances that are included in the minimum list of chemicals identified for demonstrating the accuracy and reliability of test methods that are structurally and functionally similar to the validated reference test method, and were selected from the 163 reference chemicals that were originally used to validate the reference test method (Corrositex®) (7) (10) (14). The goal of this selection process was to include, to the extent possible, chemicals that: were representative of the range of corrosivity responses (e.g. non-corrosives; UN Packing Groups I, II, and III corrosives) that the validated reference test method is capable of measuring or predicting; were representative of the chemical classes used during the validation process; have chemical structures that were well-defined; induced reproducible results in the validated reference test method; induced definitive results in the in vivo reference test; were commercially available; and were not associated with prohibitive disposal costs (14).
(28) Substances tested neat or with purity 90 %
(29) The corresponding UN Packing groups are I, II and III, respectively, for the UN GHS Sub-categories 1A, 1B and 1C. NC; Non-corrosive.
(30) Test chemicals with high acid/alkaline reserve (6)
(31) Test chemicals with low acid/alkaline reserve (6)
(32) UN GHS Subcategories 1A, 1B and 1C correspond to UN packing groups I, II and III respectively
(33) Before June 2016, this cell line was designated as BG1Luc cell line. BG-1 cells were originally described by Geisinger et al. (1998) (35) and were later characterized by researchers at the National Institute of Environmental Health Sciences (NIEHS) (36). Relatively recently, it was discovered that there exist two different variants of BG-1 cells being used by researchers, BG-1 Fr and BG-1 NIEHS. In-depth analysis, including DNA testing, of these two BG-1 variant cell lines carried out by Li and coworkers (2014) (37) showed that the BG-1 Fr was unique and that the BG-1 NIEHS, i.e. the original cell line used to develop the assay, was not the BG1 human ovarian carcinoma cell line, but was instead a variant of the MCF7 human breast cancer cell line. The cell line used in the assay, originally referred to as BG1Luc4E2 (38), will now be designated as VM7Luc4E2 (“V” = variant; “M7” = MCF7 cells). Likewise, the assay will now be designated as the VM7Luc ER TA. While this changes the origin of the cell line upon which the assay is based, it does not affect published validation studies nor the utility and application of this assay for screening of estrogenic/anti-estrogenic chemicals.
(1) Common substances tested in the STTA and VM7Luc ER TA assays that were designated as ER agonists or negatives and used to evaluate accuracy in the VM7Luc ER TA validation study (ICCVAM VM7Luc ER TA Evaluation Report, Table 4-1 (3)).
(2) Maximum concentration tested in the absence of limitations due to cytotoxicity or insolubility was 1 × 10-5 M (STTA Assay) and 1 × 10-3 M (VM7Luc ER TA Assay).
(34) Number in parenthesis represents the test results classified as positive (POS) or negative (NEG) over the total number of referenced studies.
(35) Values reported in Draft Report of Pre-validation and Inter-laboratory Validation For Stably Transfected Transcriptional Activation (TA) Assay to Detect Estrogenic Activity - The Human Estrogen Receptor Alpha Mediated Reporter Gene Assay Using hER-HeLa-9903 Cell Line (2)
(36) ICCVAM Test Method Evaluation Report on the LUMI-CELL® ER (VM7Luc ER TA) Test Method: An In Vitro Method for Identifying ER Agonists and Antagonists (3)
(37) Mean EC50 values were calculated with values reported by the laboratories of the VM7Luc ER TA validation study (XDS, ECVAM, and Hiyoshi) (3).
(38) Classification as an ER agonist or negative was based upon information in the ICCVAM Background Review Documents (BRD) for ER Binding and TA test methods (31) as well as information obtained from publications published and reviewed after the completion of the ICCVAM BRDs (2) (3) (18) (31) (33) (34).
Notes: Each assay within this test method does not have the same measurements. In some situations the EC50 cannot be calculated because a full dose response curve is not generated. Whilst with the STTA assay, the PC10 value is a key measurement, there may also be further examples where a PCx will provide useful information.
(3) Common substances tested in the STTA and VM7Luc ER TA assays that were designated as ER antagonists or negatives and used to evaluate accuracy in the VM7Luc ER TA validation study (2) (3).
(4) Maximum concentration tested in the absence of limitations due to cytotoxicity or insolubility was 1 × 10-3 M (STTA Assay) and 1 × 10-5 M (VM7Luc ER TA Assay).
(39) The Validation Report of the Stably transfected Transcriptional Activation Assay to Detect ER mediated activity, Part B (2)
(40) ICCVAM Test Method Evaluation Report on the LUMI-CELL® ER (VM7Luc ER TA) Test Method: An In Vitro Method for Identifying ER Agonists and Antagonists (3).
(41) Mean IC50 values were calculated with values reported by the laboratories of the VM7Luc ER TA validation study (XDS, ECVAM, and Hiyoshi) (3).
(42) ER STTA activity assumed from their reported effects known from the CERI historical data of ER receptor binding assay, the uterotrophic assay and information collated from the open literature (2)
(43) Classification as an ER antagonist or negative was based upon information in the ICCVAM Background Review Documents (BRD) for ER Binding and TA assays (31) as well as information obtained from publications published and reviewed after the completion of the ICCVAM BRDs (2) (3) (18) (31).
(44) Substances were assigned to one or more chemical classes using the U.S. National Library of Medicine’s Medical Subject Headings (MeSH), an internationally recognised standardised classification scheme (available at http://www.nlm.nih.gov/mesh).
(45) Substances were assigned to one or more product classes using the U.S. National Library of Medicine’s Hazardous Substances Data Bank (available at http://toxnet.nlm.nih.gov/cgi-bin/sis/htmlgen?HSDB).
(46) Classification as positive or negative for ER agonist activity was based upon the ICCVAM Background Review Documents (BRD) for ER Binding and TA assays (31) as well as empirical data and other information obtained from referenced studies published and reviewed after the completion of the ICCVAM BRDs(2) (3) (18) (31) (32) (33) (34).
(47) Values reported in Draft Report of Pre-validation and Inter-laboratory Validation For Stably Transfected Transcriptional Activation (TA) Assay to Detect Estrogenic Activity - The Human Estrogen Receptor Alpha Mediated Reporter Gene Assay Using hER-HeLa-9903 Cell Line (30).
(48) Mean EC50 values were calculated with values reported by the laboratories of the VM7Luc ER TA validation study (XDS, ECVAM, and Hiyoshi) (3).
(49) Concentrations reported were the highest concentrations tested (range finder) during the validation of the VM7Luc ER TA Assay. If concentrations differed between the laboratories, the highest concentration is reported. See table 4-10 of ICCVAM Test Method Evaluation Report; The LUMI-Cell®ER (VM7Luc ER TA) Test Method: An In Vitro Assay for Identifying Human Estrogen Receptor Agonist and Antagonist Activity of Chemicals (3).
(50) Substances were assigned into one or more chemical classes using the U.S. National Library of Medicine’s Medical Subject Headings (MeSH), an internationally recognised standardised classification scheme (available at: http://www.nlm.nih.gov/mesh).
(51) Substances were assigned into one or more product classes using the U.S. National Library of Medicine’s Hazardous Substances Database (available at: http://toxnet.nlm.nih.gov/cgi-bin/sis/htmlgen?HSDB)
(52) From Table 1 (List of Reference Chemicals (22) for Evaluation of ER Agonist Accuracy) of the Performance Standards (6)
(53) If a proficiency substance is no longer commercially available, a substance with the same classification and, comparable potency, mode of action and chemical class can be used.
(*4) classified negative according to literature review (2).
(5) Common substances tested in the STTA and VM7Luc ER TA assays that were designated as ER antagonists or negatives and used to evaluate accuracy in the VM7Luc ER TA validation study (2) (3).
(54) The Validation Report of the Stably transfected Transcriptional Activation Assay to Detect ER mediated activity, Part B (2)
(55) ICCVAM Test Method Evaluation Report on the LUMI-CELL ER (VM7Luc ER TA) Test Method: An In Vitro Method for Identifying ER Agonists and Antagonists (3).
(56) Mean IC50 values were calculated with values reported by the laboratories of the VM7Luc ER TA validation study (XDS, ECVAM, and Hiyoshi) (3).
(57) Concentrations reported were the highest concentrations tested (range finder) during the validation of the VM7Luc ER TA Assay. If concentrations differed between the laboratories, the highest concentration is reported. See table 4-11 of ICCVAM Test Method Evaluation Report; The LUMI-Cell®ER (VM7Luc ER TA) Test Method: An In Vitro Assay for Identifying Human Estrogen Receptor Agonist and Antagonist Activity of Chemicals (3).
(58) Classification as an ER antagonist or negative was based upon information in the ICCVAM Background Review Documents (BRD) for ER Binding and TA test methods (31) as well as information obtained from publications published and reviewed after the completion of the ICCVAM BRDs (2) (3) (18) (31).
(59) Substances were assigned to one or more chemical classes using the U.S. National Library of Medicine’s Medical Subject Headings (MeSH), an internationally recognised standardised classification scheme (available at http://www.nlm.nih.gov/mesh).
(60) Substances were assigned to one or more product classes using the U.S. National Library of Medicine’s Hazardous Substances Data Bank (available at http://toxnet.nlm.nih.gov/cgi-bin/sis/htmlgen?HSDB).
(61) Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (Reach), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC (OJ L 304, 22.11.2007, p. 1).
(62) JCRB Cell Bank: National Institute of Biomedical Innovation, 7-6-8 Asagi Saito, Ibaraki-shi, Osaka 567-0085, Japan Fax: +81-72-641-9812
(63) http://www.oecd.org/env/testguidelines
(64) Before June 2016, this cell line was designated as BG1Luc cell line. BG-1 cells were originally described by Geisinger et al. (1998) (12) and were later characterized by researchers at the National Institute of Environmental Health Sciences (NIEHS) (13). Relatively recently, it was discovered that there exist two different variants of BG-1 cells being used by researchers, BG-1 Fr and BG-1 NIEHS. In-depth analysis, including DNA testing, of these two BG-1 variant cell lines carried out by Li and coworkers (2014) (14) showed that the BG-1 Fr was unique and that the BG-1 NIEHS, i.e. the original cell line used to develop the assay, was not the BG1 human ovarian carcinoma cell line, but was instead a variant of the MCF7 human breast cancer cell line. The cell line used in the assay, originally referred to as BG1Luc4E2 (15), will now be designated as VM7Luc4E2 (“V” = variant; “M7” = MCF7 cells). Likewise, the assay will now be designated as the VM7Luc ER TA. While this changes the origin of the cell line upon which the assay is based, it does not affect published validation studies nor the utility and application of this assay for screening of estrogenic/anti-estrogenic chemicals.
(65) Michael S. Denison, Ph.D. Professor, Dept. of Environmental Toxicology, 4241 Meyer Hall, One Shields Ave, University of California, Davis, CA 95616, E: [email protected], (530) 754-8649
(66) Xenobiotic Detection Systems Inc. 1601 East Geer Street, Suite S, Durham NC, 27704 USA, email: [email protected], Telephone: 919-688-4804, Fax: 919-688-4404
(67) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(68) In June 2013, the Joint Meeting agreed that where possible, a more consistent use of the term “test chemical” describing what is being tested should now be applied in new and updated test methods.
(69) Chemical classes were assigned using information obtained from previous NICEATM publications and if not available, using the National Library of Medicine's Medical Subject Headings (MeSH®) (via ChemIDplus® [National Library of Medicine], available at http://chem.sis.nlm.nih.gov/chemidplus/) and structure determinations made by NICEATM.
(70) Based on results from the in vivo rabbit eye test (OECD TG 405) and using the UN GHS/CLP (1).
(71) Classification as Cat.1 is based on skin corrosive potential of 100 % sodium hydroxide (listed as a proficiency chemical with skin corrosive potential in OECD TG 435) and the criterion for UN GHS/CLP category 1 (1).
(72) Classification as 2A or 2B depends on the interpretation of the UN GHS criterion for distinguishing between these two categories, i.e., 2 out of 6 vs 4 out of 6 animals with effects at day 7 necessary to generate a Category 2A classification. The in vivo dataset included 2 studies with 3 animals each. In one study two out of three animals showed effects at day 7 warranting a Cat. 2A classification (11), whereas in the second study all endpoints in all three animals recovered to a score of zero by day 7 warranting a Cat. 2B classification (12).
(73) Classification as 2A or 2B depends on the interpretation of the UN GHS criterion for distinguishing between these two categories, i.e., 1 out of 3 vs 2 out of 3 animals with effects at day 7 necessary to generate a Category 2A classification. The in vivo study included 3 animals. All endpoints apart from corneal opacity and conjunctivae redness in one animal recovered to a score of zero by day 7 or earlier. The one animal that did not fully recover by day 7 had a corneal opacity score of 1 and a conjunctivae redness of 1 (at day 7) that fully recovered at day 14 (11).
(74) Mixtures containing substances with vapour pressure higher than 6kPa should be evaluated with care to avoid potential under-predictions, and should be justified on a case-by-case basis.
(75) Based on results obtained mainly with mono-constituent substances, although a limited amount of data also exist on the testing of mixtures. The test method is nevertheless technically applicable to the testing of multi-constituent substances and mixtures. Before use of this test method on a mixture for generating data for an intended regulatory purpose, it should be considered whether, and if so why, it may provide adequate results for that purpose. Such considerations are not needed, when there is a regulatory requirement for testing of the mixture.
(76) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(77) In June 2013, the OECD Joint Meeting agreed that where possible, a more consistent use of the term “test chemical” describing what is being tested should now be applied in new and updated OECD test guidelines.
(78) EITL: EIT for liquids in the case of SkinEthic™ HCE
(79) EITS: EIT for solids in the case of SkinEthic™ HCE
(80) Organic functional group assigned according to an OECD Toolbox 3,1 nested analysis (8).
(81) Based on results obtained with EpiOcular™ EIT in the EURL ECVAM/Cosmetics Europe Eye Irritation Validation Study (EIVS) (8).
(82) Based on results obtained with SkinEthic™ HCE EIT in the validation study (10)(11).
(83) Based on results from the in vivo rabbit eye test (TM B.5/OECD TG 405) (2)(14) and using the UN GHS.
(84) Based on results obtained in the CEFIC CONsortium for in vitro Eye Irritation testing strategy (CON4EI) Study.
(85) Classification as 2A or 2B depends on the interpretation of the UN GHS criterion for distinguishing between these two categories, i.e., 1 out of 3 vs 2 out of 3 animals with effects at day 7 necessary to generate a Category 2A classification. The in vivo study included 3 animals. All endpoints apart from corneal opacity in one animal recovered to a score of zero by day 7 or earlier. The one animal that did not fully recover by day 7 had a corneal opacity score of 1 (at day 7) that fully recovered at day 9.
(86) This acceptance limit considers the possibility of extended shipping/storage time (e.g. > 4 days), which has been shown not to impact on the performance of the test method (37).
LLOQ: Lower Limit of Quantification, defined to cover 1-2 % tissue viability, i.e., 0,8 μg/ml.
ULOQ: Upper Limit of Quantification, defined to be at least two times higher than the highest expected MTT formazan concentration in isopropanol extracts from negative controls (~70 μg/ml in the VRM), i.e., 200 μg/ml.
(*5) Limit of solubility < 1x 10-4M.
(*6) The use and classification of di-n-butyl phthalate (DBP) as a non-binder was based on testing up to 10-4 M because the substance had been observed to be insoluble at 10-3M (e.g. turbidity) in some laboratories during the pre-validation studies.
(1) During the validation study, di-n-butyl phthalate (DBP) was tested as a coded test substance at concentrations up to 10-3M. Under these conditions, some laboratories observed either a decrease in radioligand binding at the highest concentration (10-3M) and/or an ambiguous curve fit. For these runs, DBP was classified as ‘equivocal’ or ‘binder’ in 3/5 laboratories using the CERI assay and 5/6 laboratories using the FW assay (see Reference (2), Sections IV.B.3a,b and VI.A).
(6) Classification was not consistent with expected classification. Classification of 4-n-heptylphenol as ‘equivocal’ or ‘non-binder’ by 3/5 labs resulted in an average classification of equivocal. Closer inspection revealed that this was due to chemical solubility limitations that prevented the production of a full binding curve.
(7) During the validation study, benz(a)anthracene was reclassified as a non-binder (i.e. negative) based on published literature demonstrating that the in vitro estrogenic activity reported for this substance is primarily dependent upon its metabolic activation. Enzymatic metabolic activation of the substance would not be anticipated in the cell free hrER binding assays as used in this inter-laboratory validation study. Thus, the correct classification for this substance is a ‘non-binder’ when used under the experimental conditions for the FW and CERI assays.
(89) If a proficiency substance is no longer commercially available, a substance with the same ER binding classification, comparable potency, and chemical class can be used.
(90) Abbreviations: CAS RN = Chemical Abstracts Service Registry Number.
(91) Classification as an ERαBinder or Non-binder during the validation study for the CERI and FW hrER Binding Assays (2).
(92) ER binding activity was based upon the ICCVAM Background Review Documents (BRD) for ER Binding and TA assays (9) as well as empirical data and other information obtained from referenced studies published and reviewed (10) (11) (12) (13) (14) (15).
(93) Substances were assigned into one or more chemical classes using the U.S. National Library of Medicine’s Medical Subject Headings (MeSH), an internationally recognised standardised classification scheme (available at: http://www.nlm.nih.gov/mesh).
(94) Substances were assigned into one or more product classes using the U.S. National Library of Medicine’s Hazardous Substances Database (available at: http://toxnet.nlm.nih.gov/cgi-bin/sis/htmlgen?HSDB)
(95) DBP can be used as an alternate control non-binder tested with maximum concentration of 10-4 M.
(96) Limit of solubility for this substance is 10-4 M. The use and classification of di-n-butyl phthalate (DBP) as a non-binder has been based on testing up to 10-4 M because the substance had been observed to be insoluble at 10-3M (e.g. turbidity) in some laboratories during the pre-validation studies.
(8) Mean (n) ± Standard Deviation (SD) were calculated using curve fit parameter estimates (4-parameter Hill Equation) for control runs conducted in four laboratories during the validation study (see Annex N of Reference 2).
(9) The 95 % confidence intervals are provided as a guide for acceptability criteria.
(10) Testing of norethindrone was optional for Subtask 4 during validation study (see Reference 2, see Subtask 4). Thus, the mean ± SD (n) were calculated using curve fit estimates (4-parameter Hill equation) for control runs conducted in two laboratories.
The range for the IC50 will be dependent upon the Kd of the receptor preparation and concentration of radiolabelled ligand used within each laboratory. Appropriate adjustment for the range of the IC50 based upon the conditions used to conduct the assay will be acceptable.
(*7) The hot serial dilutions of [3H]-labelled estradiol here should be directly added into 200 μl of scintillation fluid in wells G1 – H12.
(*8) real blank, well not used
(*9) blank not used during the incubation, but used to confirm the total radioactivity added.
(11) Mean ± Standard Deviation (SD) with (sample size (n) were calculated using curve fit estimates (4-parameter Hill equation) for control runs conducted in four laboratories during the validation study (see Annex N of reference 2).
(12) The 95 % confidence are provided as a guide for acceptability criteria.
(13) Testing of norethindrone was optional for Subtask 4 during validation study (see Reference 2, see Subtask 4). Thus, the mean ± SD (n) were calculated using curve fit estimates (4-parameter Hill equation) for control runs conducted in two laboratories.
The range for the IC50 will be dependent upon the Kd of the receptor preparation and concentration of radiolabelled ligand used within each laboratory. Appropriate adjustment for the range of the IC50 based upon the conditions used to conduct the assay will be acceptable.
(*10) The indicated concentrations here are the final concentrations in each well
(*11) The dilutions of unlabelled E2 and [3H]E2 can be prepared in a different plate.
(*12) If an LSC for microplates is used for measuring dpms, the preparation of hot ligand alone in the same assay plate of TB and NSB wells is not appropriate. The hot ligand alone should be prepared in a different plate.
(*13) If centrifugation is used to separate DCC, the 50 μl of supernatant should be measured by LSC in order to avoid contamination of DCC.
(97) Sample set up for the standards microtiter plate to be run with each experiment.
(98) Note that this microtiter plate is made using the dilutions made in the dilution plate described for the standards in the previous sections.
In this example, the weak binder is norethinodrel (NE)
(*14) real blank, well not used
(*15) blank, not used during the incubation, but used to confirm the total radioactivity added.
(*16) properly prepared to obtain final concentration within the acceptable solvent concentration
(*17) Note that the "hotspace" wells are empty during incubation. The 10 μl are added only for scintillation counting.
(99) Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006, OJ L 353/1, 31.12.2008
(100) In June 2013, the OECD Joint Meeting agreed that where possible, a more consistent use of the term "test chemical" describing what is being tested should be applied in new and updated OECD test guidelines.
(101) This sentence was proposed and agreed at the April 2014 WNT meeting
(102) The in vivo hazard (and potency) prediction is based on LLNA data (3) (14). The in vivo potency is derived using the criteria proposed by ECETOC (24).
(103) Based on historical observed values (13) (25).
(104) Historically, a majority of negative results have been obtained for this marker and therefore a negative result is mostly expected. The range provided was defined on the basis of the few historical positive results observed. In case a positive result is obtained, the EC value should be within the reported reference range.
(105) The in vivo hazard and (potency) prediction is based on LLNA data (1) (8). The in vivo potency is derived using the criteria proposed by ECETOC (17).
(106) Based on historical observed values (1) (8).
(107) Complete medium: RPMI-1640 medium supplemented with 10 % foetal calf serum, 2 mM L-glutamine, 100 units/ml penicillin and 100 μg/ml streptomycin (8).
(108) The in vivo potency is derived using the criteria proposed by ECETOC (19).
(109) Based on historical observed values (1) (6).
(110) CV05 and IL-8 Luc MIT were calculated using water solubility given by EPI SuiteTM.
(111) CV05: the minimum concentration at which chemicals show less than 0,05 of Inh-GAPLA.
(112) MIT: the lowest concentrations at which a chemical satisfies the positive criteria.
(*18) These endpoints are to be statistically analysed
(*19) All endpoints are analysed statistically.
(*20) Day 0 is defined as the day hCG injection is done.
(*21) The first day of Week 0 is the median metamorphosis date in control animals.
(113) Nuclease-free water
(114) In accordance to Article 4.1 of Directive 2004/37/EC of the European Parliament and of the Council of 29 April 2004 on the protection of workers from the risks related to exposure to carcinogens or mutagens at work (Sixth individual Directive within the meaning of Article 16(1) of Council Directive 89/391/EEC) (OJ L 158, 30.4.2004, p. 50).