Not effective Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships ( Official Journal of the European Union L 141 of 28 May 2016 )
Smernica č. 844/2016
Important dates
Documents and links
Corrigendum to Commission Directive (EU) 2016/844 of 27 May 2016 amending Directive 2009/45/EC of the European Parliament and of the Council on safety rules and standards for passenger ships
On page 55, in Table 5.1(a) in paragraph (2), subparagraph (h) of the Annex, concerning the Annex to Directive 2009/45/EC:
for:
‘Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
|
Spaces |
|
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
|
Control stations |
(1) |
A-0e |
A-0 |
60 |
A-0 |
A-15 |
A-60 |
A-15 |
A-60 |
A-60 |
* |
A-60 |
|
Corridors |
(2) |
|
Ce |
B-0e |
A-0e B-0e |
B-0e |
A-60 |
A-15 |
A-60 |
A-15 A-0d |
* |
A-30 |
|
Accommodation spaces |
(3) |
|
|
Ce |
A-0e B-0e |
B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 A-0d |
|
Stairways |
(4) |
|
|
|
A-0e B-0e |
A-0e B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 |
|
Service spaces (low risk) |
(5) |
|
|
|
|
Ce |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
|
Machinery spaces of category A |
(6) |
|
|
|
|
|
* |
A-0 |
A-0 |
A-60 |
* |
A-60 |
|
Other machinery spaces |
(7) |
|
|
|
|
|
|
A-0b |
A-0 |
A-0 |
* |
A-0 |
|
Cargo spaces |
(8) |
|
|
|
|
|
|
|
* |
A-0 |
* |
A-0 |
|
Service spaces (high risk) |
(9) |
|
|
|
|
|
|
|
|
A-0b |
* |
A-30 |
|
Open decks |
(10) |
|
|
|
|
|
|
|
|
|
|
A-0 |
|
Special category and Ro-Ro spaces |
(11) |
|
|
|
|
|
|
|
|
|
|
A-30’ |
read:
‘Table 5.1(a)
Fire integrity of bulkheads separating adjacent spaces
|
Spaces |
|
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
|
Control stations |
(1) |
A-0c |
A-0 |
A-60 |
A-0 |
A-15 |
A-60 |
A-15 |
A-60 |
A-60 |
* |
A-60 |
|
Corridors |
(2) |
|
Ce |
B-0e |
A-0a B-0e |
B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 |
|
Accommodation spaces |
(3) |
|
|
Ce |
A-0a B-0e |
B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 A-0d |
|
Stairways |
(4) |
|
|
|
A-0a B-0e |
A-0a B-0e |
A-60 |
A-0 |
A-0 |
A-15 A-0d |
* |
A-30 |
|
Service spaces (low risk) |
(5) |
|
|
|
|
Ce |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
|
Machinery spaces of category A |
(6) |
|
|
|
|
|
* |
A-0 |
A-0 |
A-60 |
* |
A-60 |
|
Other machinery spaces |
(7) |
|
|
|
|
|
|
A-0b |
A-0 |
A-0 |
* |
A-0 |
|
Cargo spaces |
(8) |
|
|
|
|
|
|
|
* |
A-0 |
* |
A-0 |
|
Service spaces (high risk) |
(9) |
|
|
|
|
|
|
|
|
A-0b |
* |
A-30 |
|
Open decks |
(10) |
|
|
|
|
|
|
|
|
|
|
A-0 |
|
Special category spaces |
(11) |
|
|
|
|
|
|
|
|
|
|
A-30’ |
on page 56, in Table 5.2(a) in paragraph (2), subparagraph (i) of the Annex, concerning the Annex to Directive 2009/45/EC:
for:
‘Table 5.2(a)
Fire integrity of decks separating adjacent spaces
|
Spaces Below↓ |
Spaces → Above |
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
|
Control stations |
(1) |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
|
Corridors |
(2) |
A-0 |
* |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
|
Accommodation spaces |
(3) |
A-60 |
A-0 |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 A-0d |
|
Stairways |
(4) |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
|
Service spaces (low risk) |
(5) |
A-15 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
|
Machinery spaces of category A |
(6) |
A-60 |
A-60 |
A-60 |
A-60 |
A-60 |
* |
A-60f |
A-30 |
A-60 |
* |
A-60 |
|
Other machinery spaces |
(7) |
A-15 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-0 |
* |
A-0 |
|
Cargo spaces |
(8) |
A-60 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
* |
A-0 |
|
Service spaces (high risk) |
(9) |
A-60 |
A-30 A-0d |
A-30 A-0d |
A-30 A-0d |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
|
Open decks |
(10) |
* |
* |
* |
* |
* |
* |
* |
* |
* |
— |
A-0 |
|
Special category and Ro-Ro spaces |
(11) |
A-60 |
A-30 |
A-30 A-0d |
A-30 |
A-0 |
A-60 |
A-0 |
A-0 |
A-30 |
A-0 |
A-30’ |
read:
‘Table 5.2(a)
Fire integrity of decks separating adjacent spaces
|
Space Below↓ Space Above → |
(1) |
(2) |
(3) |
(4) |
(5) |
(6) |
(7) |
(8) |
(9) |
(10) |
(11) |
|
|
Control stations |
(1) |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
|
Corridors |
(2) |
A-0 |
* |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
|
Accommodation spaces |
(3) |
A-60 |
A-0 |
* |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 A-0d |
|
Stairways |
(4) |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
|
Service spaces (low risk) |
(5) |
A-15 |
A-0 |
A-0 |
A-0 |
* |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
|
Machinery spaces of category A |
(6) |
A-60 |
A-60 |
A-60 |
A-60 |
A-60 |
* |
A-60f |
A-30 |
A-60 |
* |
A-60 |
|
Other machinery spaces |
(7) |
A-15 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
A-0 |
* |
A-0 |
|
Cargo spaces |
(8) |
A-60 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
A-0 |
* |
A-0 |
* |
A-0 |
|
Service spaces (high risk) |
(9) |
A-60 |
A-30 A-0d |
A-30 A-0d |
A-30 A-0d |
A-0 |
A-60 |
A-0 |
A-0 |
A-0 |
* |
A-30 |
|
Open decks |
(10) |
* |
* |
* |
* |
* |
* |
* |
* |
* |
— |
A-0 |
|
Special category spaces |
(11) |
A-60 |
A-30 |
A-30 A-0d |
A-30 |
A-0 |
A-60 |
A-0 |
A-0 |
A-30 |
A-0 |
A-30’ |
on page 61, in paragraph (2)(l) of the Annex, concerning point 7 of the rule 9a in Annex I to Directive 2009/45/EC:
for:
‘.7 Ventilation systems for laundries in passenger ships carrying more than 36 passengers
Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B//.2.2 shall be fitted with:’,
read:
‘.7 Ventilation systems for laundries in passenger ships carrying more than 36 passengers
Exhaust ducts from laundries and drying rooms of category (13) spaces as defined in Regulation II-2/B/4.2.2 shall be fitted with:’.